EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Femoral resection accuracy and precision in manual caliper‐verified kinematic alignment total knee arthroplasty

David Forrest Scott iD, Emma N Horton

Journal of Experimental Orthopaedics · 2025-04 · 12 (2)

DOI: 10.1002/jeo2.70234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 17.04.2025. Verfasst von David Forrest Scott und 1 weiteren Autor:innen. Beteiligte Einrichtung: Spokane Joint Replacement Center, Inc. Spokane Washington USA. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The accuracy and precision of bone resections in total knee arthroplasty (TKA) are essential to avoid poor implant positioning, which can lead to component wear, pain, and instability, reducing patient satisfaction and implant survivorship. Technology‐assisted TKA techniques aim to improve accuracy but come with added costs, increased operative time, and varying success in clinical outcomes. Caliper‐verified kinematic alignment (KA) attempts to restore the joint line by precisely measuring resections to equal implant thickness. We evaluated the accuracy and precision of caliper‐verified KA‐TKA performed with manual instruments. We hypothesised that this technique would achieve high accuracy and precision, with an average absolute difference between actual and target distal and posterior femoral resection measurements of ≤ 0.5 mm.

Methods

385 consecutive patients underwent primary unrestricted caliper‐verified KA‐TKA with manual instrumentation. The thickness of the distal medial (DM), distal lateral (DL), posterior medial (PM) and posterior lateral (PL) femoral condyle resections were measured with a caliper and compared to a target determined by the degree of cartilage loss, saw blade kerf, and femoral component thickness.

Results

The mean differences between the resected and target thicknesses for DM, DL, PM and PL femoral resections were 0.1 ± 0.2 mm, 0.1 ± 0.3 mm, 0.3 ± 0.5 mm and 0.2 ± 0.4 mm, respectively (mean ± std. dev.). Most femoral resections were within 0.5 mm of the target—97.7%, 94.5%, 85.7% and 89.4% of DM, DL, PM and PL resections, respectively.

Conclusion

Manual caliper‐verified KA‐TKA achieved highly accurate and precise femoral resections with absolute differences from target that averaged 0.175 mm. This simple, logical, efficient, and reproducible surgical technique may be an option for surgeons contemplating the use of technology‐assisted options, such as patient‐specific instrumentation or robotic arm‐assisted TKA, and surgeons without access to such technologies. Level of Evidence Level II.

Schlagwörter

Stichwörter der Autor:innen

kinematic alignmentpatient‐specific instrumentationrobotic arm‐assistedtotal knee arthroplasty

Autor:innen und Institutionen

  • Spokane Joint Replacement Center, Inc. Spokane Washington USA.
  • Washington State University Elson S. Floyd College of Medicine Spokane Washington USA.

ORCID-Profile: David Forrest Scott

Zitieren

APA

Scott, D. F., & Horton, E. N. (2025). Femoral resection accuracy and precision in manual caliper‐verified kinematic alignment total knee arthroplasty. Journal of Experimental Orthopaedics, 12(2). https://doi.org/10.1002/jeo2.70234

Vancouver

Scott DF, Horton EN. Femoral resection accuracy and precision in manual caliper‐verified kinematic alignment total knee arthroplasty. Journal of Experimental Orthopaedics. 2025;12(2). doi:10.1002/jeo2.70234

BibTeX
@article{Scott2025,
  author = {Scott, David Forrest and Horton, Emma N},
  title = {Femoral resection accuracy and precision in manual caliper‐verified kinematic alignment total knee arthroplasty},
  journal = {Journal of Experimental Orthopaedics},
  year = {2025},
  volume = {12},
  number = {2},
  doi = {10.1002/jeo2.70234}
}
Kostenlos starten →