EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Normative values of radiographic parameters in coronal plane lower limb alignment in a general Japanese population: A cross‐sectional study in the Iwaki cohort

Ryoto Kura, Eiji Sasaki iD, Eitaro Sato, Yukiko Sakamoto, Yuka Kimura, Kyota Ishibashi, Eiichi Tsuda, Yasuyuki Ishibashi

Journal of Experimental Orthopaedics · 2025-04 · 12 (2)

DOI: 10.1002/jeo2.70207 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 01.04.2025. Verfasst von Ryoto Kura und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Graduate School of Medicine Hirosaki University Hirosaki Japan. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to estimate normative values of radiographic parameters in lower limb alignment and investigate age‐related changes in lower limb alignment in a general Japanese population.

Methods

A total of 1474 knees in 737 volunteers (307 men and 430 women) who participated in the Iwaki cohort study were enroled. Standing anterior‐posterior radiographs were assessed using the Kellgren–Lawrence (KL) grading scale, with KL ≥Grade 2 defined as osteoarthritis (OA). Radiographic parameters measured included the hip–knee–ankle angle (HKAA), femorotibial angle (FTA), mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), joint line convergence angle (JLCA) and weight‐bearing line ratio (WBLR). Normative values were estimated as the mean ± 2 standard deviations for all participants without knee OA (KOA) aged 18–39 years, and associations with age were analyzed.

Results

Normative values in overall young healthy participants were: HKAA, 1.8 ± 5.1°; FTA, 175.7 ± 6.5°; mLDFA, 86.4 ± 3.4°; MPTA, 85.8 ± 4.1°; JLCA, 1.2 ± 2.7° and WBLR, 39.7 ± 23.7%. The HKAA, FTA, MPTA and WBLR values differed significantly between sexes. In men without KOA, HKAA, FTA, MPTA and WBLR values correlated very weakly with age ( r = −0.189 to 0.220). In contrast, only HKAA correlated very weakly with age in women without KOA ( r = 0.096).

Conclusions

Estimated normative values of radiographic parameters in coronal plane lower limb alignment differed significantly between sexes. These data might be useful when considering the aetiology and therapeutic strategy for KOA. Level of Evidence Level II.

Schlagwörter

Stichwörter der Autor:innen

coronal plane alignment of the kneecross‐sectional studygeneral populationknee osteoarthritislower limb alignmentnormative value

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Graduate School of Medicine Hirosaki University Hirosaki Japan.
  • Department of Rehabilitation Medicine, Graduate School of Medicine Hirosaki University Hirosaki Japan.

ORCID-Profile: Eiji Sasaki

Zitieren

APA

Kura, R., Sasaki, E., Sato, E., Sakamoto, Y., Kimura, Y., Ishibashi, K., Tsuda, E., & Ishibashi, Y. (2025). Normative values of radiographic parameters in coronal plane lower limb alignment in a general Japanese population: A cross‐sectional study in the Iwaki cohort. Journal of Experimental Orthopaedics, 12(2). https://doi.org/10.1002/jeo2.70207

Vancouver

Kura R, Sasaki E, Sato E, Sakamoto Y, Kimura Y, Ishibashi K, et al. Normative values of radiographic parameters in coronal plane lower limb alignment in a general Japanese population: A cross‐sectional study in the Iwaki cohort. Journal of Experimental Orthopaedics. 2025;12(2). doi:10.1002/jeo2.70207

BibTeX
@article{Kura2025,
  author = {Kura, Ryoto and Sasaki, Eiji and Sato, Eitaro and Sakamoto, Yukiko and Kimura, Yuka and Ishibashi, Kyota and Tsuda, Eiichi and Ishibashi, Yasuyuki},
  title = {Normative values of radiographic parameters in coronal plane lower limb alignment in a general Japanese population: A cross‐sectional study in the Iwaki cohort},
  journal = {Journal of Experimental Orthopaedics},
  year = {2025},
  volume = {12},
  number = {2},
  doi = {10.1002/jeo2.70207}
}
Kostenlos starten →