EUVIMEDEUVIMED entdecken
Crossref

Lightweight Truncated Fused‐ MirrorNet for Classification and Analysis of Histopathology Images

Amit Kumar Chanchal, Shyam Lal

Microscopy Research and Technique · 2026

DOI: 10.1002/jemt.70127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy Research and Technique, 2026. Verfasst von Amit Kumar Chanchal und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Computing, MIT Vishwaprayag University, Solapur, Maharashtra, India. Hauptthemen laut MEDLINE: Kidney Neoplasms, Image Processing, Computer-Assisted, Carcinoma, Renal Cell. Die Arbeit nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Renal cell carcinoma is the primary cause of cancer‐related mortality, highlighting the importance of early detection and accurate diagnosis. Manual histopathology image classification methods include limitations such as labor effort, time consumption, and interpathologist variations, which can lead to misdiagnosis, especially in the early stages. An autonomous solution based on deep learning is essential to overcome these constraints. However, vision‐based models require significant processing resources and data sets, which pose difficulties for low‐end infrastructures. In this study, we have described an approach for analyzing histopathology images using a lightweight truncated Fused‐MirrorNet model. With its mirrored architecture, we use partial layer freezing and feature fusion approaches to improve performance. In kidney histopathology image analysis, our suggested strategy outperforms existing CNN and vision transformer models in histopathology image classification. We significantly reduced training time while preserving classification accuracy. The proposed model is deployable, scalable, and reproducible, allowing it to be used on low‐end devices. Our strategy also makes it easier to create vision‐based deep learning models by removing the requirement for sophisticated computational methodologies and procedures. The proposed model and the comparison models were trained and evaluated using histopathology images from two datasets. The experimental results reveal that the proposed model (Fused‐MirrorNet) surpassed the performance of state‐of‐the‐art models used for the classification of histopathology images. The proposed model achieves an accuracy of 92.60% and 90.00% in the TCGA kidney and BreakHis datasets, respectively. These findings indicate that the research conducted to develop the suggested model produced favorable outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Kidney NeoplasmsImage Processing, Computer-AssistedCarcinoma, Renal CellConvolutional Neural NetworksHumansKidneyDeep Learning

Stichwörter der Autor:innen

CNNfeature fusionhistopathology imageskidney cancer detectionvision transformer

Autor:innen und Institutionen

  • School of Computing, MIT Vishwaprayag University, Solapur, Maharashtra, India.
  • Department of Electronics and Communication Engineering, National Institute of Technology Karnataka, SurathkalMangaluru, Karnataka, India.

Zitieren

APA

Chanchal, A. K., & Lal, S. (2026). Lightweight Truncated Fused‐ MirrorNet for Classification and Analysis of Histopathology Images. Microscopy Research and Technique. https://doi.org/10.1002/jemt.70127

Vancouver

Chanchal AK, Lal S. Lightweight Truncated Fused‐ MirrorNet for Classification and Analysis of Histopathology Images. Microscopy Research and Technique. 2026. doi:10.1002/jemt.70127

BibTeX
@article{Chanchal2026,
  author = {Chanchal, Amit Kumar and Lal, Shyam},
  title = {Lightweight Truncated Fused‐ MirrorNet for Classification and Analysis of Histopathology Images},
  journal = {Microscopy Research and Technique},
  year = {2026},
  doi = {10.1002/jemt.70127}
}
Kostenlos starten →