External Validation of a Deep Learning‐Based Artificial Intelligence System for Ultrasound Diagnosis of Thyroid Nodules: A Two‐Center Retrospective Study
Journal of Clinical Ultrasound · 2026
DOI: 10.1002/jcu.70275 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Clinical Ultrasound, 2026. Verfasst von Yang Tang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Thyroid Nodule, Deep Learning, Artificial Intelligence, Image Interpretation, Computer-Assisted. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
Objectives
To investigate the performance of an artificial intelligence (AI) diagnostic system for thyroid nodule sonography based on deep learning convolutional neural network (CNN). Materials and Methods We retrospectively included 485 thyroid nodules with definite pathology in two tertiary hospitals. The AI diagnostic system was constructed for automatic detection and diagnosis of nodules based on deep learning CNN equipped with image mode and video mode. One gray‐scale ultrasound (US) image of each nodule from the two hospitals was selected for diagnosis in image mode (AI model img ). A US video of each nodule from the second hospital was analyzed in video mode (AI model vid ). Performance of AI model img , AI model vid , and three radiologists with 3–15 years of US experience was evaluated. Sonographic features probably influencing the accuracy of AI model img were screened out by binary logistic regression analysis.
Results
Although the experienced radiologist achieved highest sensitivity, accuracy and the area under the receiver operating characteristic curve (AUC) compared to AI model img and two junior radiologists, there was no significant difference between AUCs of AI model img and experienced radiologist (0.770 [0.718–0.816] vs. 0.799 [0.750–0.843] in first hospital dataset, p = 0.253; 0.731 [0.660–0.794] vs. 0.780 [0.712–0.838] in second hospital dataset, p = 0.105). When US videos were used for diagnosis instead of images, significantly higher specificity (0.575 [0.489–0.661] vs. 0.693 [0.613–0.773], p = 0.003), accuracy (0.667 [0.598–0.736] vs. 0.744 [0.681–0.808], p = 0.002) and AUC (0.731 [0.660–0.794] vs. 0.780 [0.713–0.839], p = 0.016) were achieved by AI model vid . AI model img was more likely to make a correct diagnosis in benign nodules with circumscribed margin (OR = 3.46, p = 0.003), hyperechoic or isoechoic echogenicity (OR = 8.83, p < 0.001) and none of echogenic foci or with large comet‐tail artifacts (OR = 2.28, p = 0.041). Respectively, AI model img acquired higher accuracy in malignant nodules with hypoechoic or very hypoechoic echogenicity (OR = 3.33, p = 0.034) and irregular margin (OR = 4.51, p = 0.003). In TR1 and TR2 (ACR TI‐RADS risk level) nodules, accuracy of AI model img was 100% (6 of 6) and 90% (27 of 30).
Conclusion
The AI diagnostic system is feasible and reliable in automatic detection and diagnosis of thyroid nodules and acquires superior performance applied in US videos. Sonographic features of thyroid nodules are a crucial factor influencing the accuracy of the AI model.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China.
- Shanghai Institute of Medical Imaging, Shanghai, China.
ORCID-Profile: Yang Tang
Zitieren
APA
Tang, Y., Xu, Y. D., Zhao, C. K., Fan, P. L., Jin, Y. J., Ji, Z. B., Han, H., Xu, H. X., & Xu, B. H. (2026). External Validation of a Deep Learning‐Based Artificial Intelligence System for Ultrasound Diagnosis of Thyroid Nodules: A Two‐Center Retrospective Study. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.70275
Vancouver
Tang Y, Xu YD, Zhao CK, Fan PL, Jin YJ, Ji ZB, et al. External Validation of a Deep Learning‐Based Artificial Intelligence System for Ultrasound Diagnosis of Thyroid Nodules: A Two‐Center Retrospective Study. Journal of Clinical Ultrasound. 2026. doi:10.1002/jcu.70275
BibTeX
@article{Tang2026,
author = {Tang, Yang and Xu, Ya-Dan and Zhao, Chong-Ke and Fan, Pei-Li and Jin, Yun-Jie and Ji, Zheng-Biao and Han, Hong and Xu, Hui-Xiong and Xu, Ben-Hua},
title = {External Validation of a Deep Learning‐Based Artificial Intelligence System for Ultrasound Diagnosis of Thyroid Nodules: A Two‐Center Retrospective Study},
journal = {Journal of Clinical Ultrasound},
year = {2026},
doi = {10.1002/jcu.70275}
}
EUVIMED