EUVIMEDEUVIMED entdecken
Fallbericht

Acute “Crack‐Like” Hemorrhage of the Thyroid During Fine‐Needle Aspiration Biopsy: A Case Report

Yuren Zhang iD, Li Yang, Qing Ni iD

Journal of Clinical Ultrasound · 2026

DOI: 10.1002/jcu.70178 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Clinical Ultrasound, 2026. Verfasst von Yuren Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology, China Academy of Chinese Medical Sciences Guang'anmen Hospital, Beijing, China. Hauptthemen laut MEDLINE: Biopsy, Fine-Needle, Hemorrhage, Thyroid Gland. Die Arbeit nennt 14 Literaturangaben. Gefördert von: Scientific and Technological Innovation Project of China Academy of Chinese Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fine‐needle aspiration biopsy (FNAB) is the preferred pathological examination to exclude thyroid cancer. We describe two case studies of acute thyroid lytic hemorrhage and swelling with pain during FNAB. We observed hemorrhages with a crack‐like appearance and swelling during the first needle prick, accompanied by pain, in two patients with no coagulation dysfunction. Symptoms were relieved after the intervention. Thyroid hemorrhage with a crack‐like pattern is a rare acute hemorrhagic complication of FNAB. The cause is unclear, and an allergic reaction of the glands could not be excluded. Emergency measures must be prepared in advance, as unpredictable complications may occur during FNAB.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biopsy, Fine-NeedleHemorrhageThyroid GlandFemaleHumansMaleMiddle AgedAcute DiseaseDiagnosis, DifferentialThyroid Diseases

Stichwörter der Autor:innen

acute hemorrhagic complicationcase reportcoagulation dysfunctionfine needle biopsyhemorrhagethyroid cancer

Autor:innen und Institutionen

  • Department of Endocrinology, China Academy of Chinese Medical Sciences Guang'anmen Hospital, Beijing, China.
  • Department of Ultrasound, China Academy of Chinese Medical Sciences Guang'anmen Hospital, Beijing, China.

ORCID-Profile: Yuren Zhang, Qing Ni

Förderung

  • Scientific and Technological Innovation Project of China Academy of Chinese Medical Sciences

Zitieren

APA

Zhang, Y., Yang, L., & Ni, Q. (2026). Acute “Crack‐Like” Hemorrhage of the Thyroid During Fine‐Needle Aspiration Biopsy: A Case Report. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.70178

Vancouver

Zhang Y, Yang L, Ni Q. Acute “Crack‐Like” Hemorrhage of the Thyroid During Fine‐Needle Aspiration Biopsy: A Case Report. Journal of Clinical Ultrasound. 2026. doi:10.1002/jcu.70178

BibTeX
@article{Zhang2026,
  author = {Zhang, Yuren and Yang, Li and Ni, Qing},
  title = {Acute “Crack‐Like” Hemorrhage of the Thyroid During Fine‐Needle Aspiration Biopsy: A Case Report},
  journal = {Journal of Clinical Ultrasound},
  year = {2026},
  doi = {10.1002/jcu.70178}
}
Kostenlos starten →