EUVIMEDEUVIMED entdecken
Beobachtungsstudie

The Predictive Role of Cervical Volume, Cervical Length, and Uterocervical Angle for Preterm Birth

Ceren Eker Karaman iD, Burcu Dincgez iD, Nefise Nazlı Yenigül iD, Gulten Ozgen iD

Journal of Clinical Ultrasound · 2026

DOI: 10.1002/jcu.70014 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Clinical Ultrasound, 2026. Verfasst von Ceren Eker Karaman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Van Research and Training Hospital, Van, Turkey. Hauptthemen laut MEDLINE: Premature Birth, Cervix Uteri, Ultrasonography, Prenatal, Cervical Length Measurement. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Predictive tests for preterm birth are considered extremely important considering the associated morbidities. Here, we aimed to assess the predictive role of cervical volume for preterm birth and compare this role with uterocervical angle and cervical length. Additionally, we aimed to evaluate the success of combinations of cervical volume, uterocervical angle, and cervical length in predicting preterm birth.

Methods

A total of 485 pregnant women between 16 and 24th gestational weeks of gestation were included in this prospective observational study. Then, the patients were grouped as preterm and term births. The clinical characteristics, obstetric outcomes, and sonographic findings including uterocervical angle, cervical length, and cervical volume were compared between groups. The predictive roles of sonographic findings for preterm birth were analyzed by receiver operating characteristic curve and regression analysis.

Result

Cervical length ≤ 35.7 mm predicted preterm birth with 81.16% sensitivity and 79.81% specificity ( p < 0.001, AUC = 0.843) while uterocervical angle > 94.9° predicted it with 98.55% sensitivity and 54.57% specificity ( p < 0.001, AUC = 0.751). Cervical volume ≤ 30.4 mm 3 predicted preterm birth with 86.96% sensitivity and 77.4% specificity ( p < 0.001, AUC = 0.886). No significant difference was found between cervical length and cervical volume, both of which are superior to uterocervical angle in predicting preterm birth. The combination of cervical length, uterocervical angle, and cervical volume increases the risk of preterm birth by approximately 153 times.

Conclusion

Cervical volume could be considered a new predictor for preterm birth. Moreover, its use with cervical length and uterocervical angle may bring us closer to a more successful prediction of preterm birth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Premature BirthCervix UteriUltrasonography, PrenatalCervical Length MeasurementHumansFemalePregnancyProspective StudiesAdultPredictive Value of TestsSensitivity and Specificity

Stichwörter der Autor:innen

cervical lengthcervical volumepreterm birthuterocervical angle

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Van Research and Training Hospital, Van, Turkey.
  • Department of Obstetrics and Gynecology, University of Health Sciences, BursaYuksek Ihtisas Research and Training Hospital, Bursa, Turkey.

ORCID-Profile: Ceren Eker Karaman, Burcu Dincgez, Nefise Nazlı Yenigül, Gulten Ozgen

Zitieren

APA

Karaman, C. E., Dincgez, B., Yenigül, N. N., & Ozgen, G. (2026). The Predictive Role of Cervical Volume, Cervical Length, and Uterocervical Angle for Preterm Birth. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.70014

Vancouver

Karaman CE, Dincgez B, Yenigül NN, Ozgen G. The Predictive Role of Cervical Volume, Cervical Length, and Uterocervical Angle for Preterm Birth. Journal of Clinical Ultrasound. 2026. doi:10.1002/jcu.70014

BibTeX
@article{Karaman2026,
  author = {Karaman, Ceren Eker and Dincgez, Burcu and Yenigül, Nefise Nazlı and Ozgen, Gulten},
  title = {The Predictive Role of Cervical Volume, Cervical Length, and Uterocervical Angle for Preterm Birth},
  journal = {Journal of Clinical Ultrasound},
  year = {2026},
  doi = {10.1002/jcu.70014}
}
Kostenlos starten →