The Clinical Value of Real‐Time Shear Wave Elastography in Evaluating Closed Complete Achilles Tendon Ruptures
Journal of Clinical Ultrasound · 2025-11 · 53 (9) · 2100-2107
DOI: 10.1002/jcu.70010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, online erschienen am 22.07.2025. Verfasst von Wenxian Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Bengbu Medical University, Bengbu, Anhui, China. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Achilles Tendon, Tendon Injuries. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Key Research and Development Project of Anhui Province, Anhui Provincial Key Research and Development Plan.
Abstract (Originalsprache)
Objective
To evaluate the clinical value of real‐time shear wave elastography (RTSWE) in diagnosing complete closed Achilles tendon ruptures (ATRs), emphasizing preoperative assessment and postoperative healing monitoring.
Methods
A total of 72 consecutive patients with ultrasound‐confirmed complete closed ATRs (68 men, 4 women) participated. Morphometric parameters, including tendon gap length, rupture‐to‐insertion distance, and tendon thickness, were assessed by conventional ultrasound. Shear wave elastography (SWE) provided quantitative biomechanical data through shear wave velocity (SWV) measurements at the proximal and distal segments of ruptured and contralateral asymptomatic tendons, as well as adjacent soleus muscles.
Results
Patients' mean age was 37.14 ± 9.58 years, with a significant male predominance (94.4%). Ruptures occurred nearly equally in the left (52.8%) and right (47.2%) tendons. Morphological changes were significant, with increased thickness at proximal [6.81 (2.72) mm vs. 4.97 (0.92) mm; p < 0.001] and distal segments [8.22 (3.10) mm vs. 4.97 (0.92) mm; p < 0.001] compared to asymptomatic tendons. SWV analysis demonstrated significantly lower stiffness at the proximal segment of ruptured tendons compared with distal segments [3.55 (1.26) m/s vs. 4.87 (1.80) m/s; p < 0.001] and contralateral tendons [4.59 (1.64) m/s vs. 4.87 (1.80) m/s; p < 0.001].
Conclusion
RTSWE provides valuable quantitative biomechanical information for preoperative planning and postoperative monitoring of complete closed ATRs. Elastographic changes remain confined to the free tendon segment without affecting the proximal musculotendinous junction of the soleus muscle, indicating compartment‐specific mechanical alterations following tendon rupture.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Bengbu Medical University, Bengbu, Anhui, China.
- Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China.
ORCID-Profile: Wenxian Yang
Förderung
- Key Research and Development Project of Anhui Province
- Anhui Provincial Key Research and Development Plan
Zitieren
APA
Yang, W., Yu, Q., Wang, Y., Li, D., Tang, X., & Liu, W. (2025). The Clinical Value of Real‐Time Shear Wave Elastography in Evaluating Closed Complete Achilles Tendon Ruptures. Journal of Clinical Ultrasound, 53(9), 2100-2107. https://doi.org/10.1002/jcu.70010
Vancouver
Yang W, Yu Q, Wang Y, Li D, Tang X, Liu W. The Clinical Value of Real‐Time Shear Wave Elastography in Evaluating Closed Complete Achilles Tendon Ruptures. Journal of Clinical Ultrasound. 2025;53(9):2100-2107. doi:10.1002/jcu.70010
BibTeX
@article{Yang2025,
author = {Yang, Wenxian and Yu, Qirui and Wang, Yuhao and Li, Dan and Tang, Xueting and Liu, Weiyong},
title = {The Clinical Value of Real‐Time Shear Wave Elastography in Evaluating Closed Complete Achilles Tendon Ruptures},
journal = {Journal of Clinical Ultrasound},
year = {2025},
volume = {53},
number = {9},
pages = {2100--2107},
doi = {10.1002/jcu.70010}
}
EUVIMED