Prospective Evaluation of Internal Cranial Fronto‐Occipital Diameter/Corpus Callosum Length Ratio on Normal Depistage and IUFGR Prenatal Ultrasound
Journal of Clinical Ultrasound · 2025
DOI: 10.1002/jcu.24057 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von M Sarreau und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Pathology and Foetopathology, Pellegrin Hospital, Bordeaux University Hospital, Bordeaux, France. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Fetal Growth Retardation, Corpus Callosum, Frontal Bone. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Introduction
Aim to explore the feasibility of assessing the relationship between the internal cranial fronto‐occipital diameter (IFOD) and corpus callosum (CC) length and compare this to fetuses with intrauterine growth restriction (IUGR). Materials and Methods Observationnal study including 989 fetuses: 912 eutrophic fetuses and 75 with IUGR. Strict quality control criteria were applied to CC measurements, which were taken in median sagittal section including the vermis. IFOD was measured along the same axis between the internal bone tables. IFOD/CC ratio was calculated and analyzed by pregnancy trimester. We compared the IFOD/CC ratio between eutrophic fetuses and those with IUGR, excluding cases with cerebral malformations or genetic disorders.
Results
IFOD/CC ratio was, on average, 3.32 (±0.91) in the first trimester (< 21 GW) for 40 patients, 2.54 (±0.18) in the second trimester (21–30 GW) for 487 patients, and 2.47 (±0.08) in the third trimester (31–38 GW) for 385 patients. The ratio decreased proportionally with advancing pregnancy. The IFOD/CC ratio was 2.51 (±0.13) in eutrophic fetuses and 2.49 (±0.10) in fetuses with IUGR, with no significant difference between the two groups (Student's t ‐test, p value = 0.18).
Conclusion
There was no significant difference between eutrophic fetuses and those with IUGR. This method appears to be quick and could offer an advantage over standard CC charts. It may also help minimize potential biases in detecting CC hypoplasia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anatomy, Pathology and Foetopathology, Pellegrin Hospital, Bordeaux University Hospital, Bordeaux, France.
- Obstetrics and Gynecology Department, Girac Hospital, Angouleme, France.
- Prenatal Diagnostic Center, La Milétrie Hospital. Poitiers University Hospital, Poitiers, France.
ORCID-Profile: M Sarreau
Zitieren
APA
Sarreau, M., Hubert, O., Couillet, A., Dahmouni, H., Vequeau-Goua, V., & Silmenova Brachot, I. (2025). Prospective Evaluation of Internal Cranial Fronto‐Occipital Diameter/Corpus Callosum Length Ratio on Normal Depistage and IUFGR Prenatal Ultrasound. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.24057
Vancouver
Sarreau M, Hubert O, Couillet A, Dahmouni H, Vequeau-Goua V, Silmenova Brachot I. Prospective Evaluation of Internal Cranial Fronto‐Occipital Diameter/Corpus Callosum Length Ratio on Normal Depistage and IUFGR Prenatal Ultrasound. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.24057
BibTeX
@article{Sarreau2025,
author = {Sarreau, M and Hubert, O and Couillet, A and Dahmouni, H and Vequeau-Goua, V and Silmenova Brachot, I},
title = {Prospective Evaluation of Internal Cranial Fronto‐Occipital Diameter/Corpus Callosum Length Ratio on Normal Depistage and IUFGR Prenatal Ultrasound},
journal = {Journal of Clinical Ultrasound},
year = {2025},
doi = {10.1002/jcu.24057}
}
EUVIMED