EUVIMEDEUVIMED entdecken
Multizentrische Studie

Dynamic AI Ultrasound‐Assisted Diagnosis System to Reduce Unnecessary Fine Needle Aspiration of Thyroid Nodules

Fang Li iD, Shuang Tao, Ma Ji, Long Liu, Ziwei Qin, Xueting Yang, Rong Wu iD, Jia Zhan iD

Journal of Clinical Ultrasound · 2025

DOI: 10.1002/jcu.24035 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Fang Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Thyroid Nodule, Artificial Intelligence, Unnecessary Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Key Research and Development Projects, Science and Technology Commission of Shanghai Municipality, National Natural Science Foundation of China (Grants No. 82130057, 82071931).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aims to compare the diagnostic efficiency of the American College of Radiology‐Thyroid Imaging, Reporting, and Data System (ACR‐TIRADS), fine‐needle aspiration (FNA) cytopathology alone, and the dynamic artificial intelligence (AI) diagnostic system. Materials and Methods A total of 1035 patients from three hospitals were included in the study. Of these, 590 were from the retrospective dataset and 445 cases were from the prospective dataset. The diagnostic accuracy of the dynamic AI system in the thyroid nodules was evaluated in comparison to the gold standard of postoperative pathology. The sensitivity, specificity, ROC, and diagnostic differences in the κ ‐factor relative to the gold standard were analyzed for the AI system and the FNA.

Results

The dynamic AI diagnostic system showed good diagnostic stability in different ages and sexes and nodules of different sizes. The diagnostic AUC of the dynamic AI system showed a significant improvement from 0.89 to 0.93 compared to ACR TI‐RADS. Compared to that of FNA cytopathology, the diagnostic efficacy of the dynamic AI system was found to be no statistical difference in both the retrospective cohort and the prospective cohort.

Conclusion

The dynamic AI diagnostic system enhances the accuracy of ACR TI‐RADS‐based diagnoses and has the potential to replace biopsies, thus reducing the necessity for invasive procedures in patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyroid NoduleArtificial IntelligenceUnnecessary ProceduresHumansFemaleMaleMiddle AgedBiopsy, Fine-NeedleRetrospective StudiesAdultUltrasonographySensitivity and SpecificityThyroid GlandAgedProspective StudiesYoung AdultReproducibility of ResultsAdolescent

Stichwörter der Autor:innen

dynamic artificial intelligencefine‐needle aspirationthyroid nodulesultrasound

Autor:innen und Institutionen

  • Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Department of Breast Surgery, Wujin Hospital Affiliated With Jiangsu University, Wujin, China.
  • Department of Ultrasound, Xuzhou Centeral Hospital of Bengbu Medical College, Xuzhou, China.

ORCID-Profile: Fang Li, Rong Wu, Jia Zhan

Förderung

  • National Key Research and Development Projects
  • Science and Technology Commission of Shanghai Municipality
  • National Natural Science Foundation of China (Grants No. 82130057, 82071931)
  • Changzhou Science and Technology Program

Zitieren

APA

Li, F., Tao, S., Ji, M., Liu, L., Qin, Z., Yang, X., Wu, R., & Zhan, J. (2025). Dynamic AI Ultrasound‐Assisted Diagnosis System to Reduce Unnecessary Fine Needle Aspiration of Thyroid Nodules. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.24035

Vancouver

Li F, Tao S, Ji M, Liu L, Qin Z, Yang X, et al. Dynamic AI Ultrasound‐Assisted Diagnosis System to Reduce Unnecessary Fine Needle Aspiration of Thyroid Nodules. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.24035

BibTeX
@article{Li2025,
  author = {Li, Fang and Tao, Shuang and Ji, Ma and Liu, Long and Qin, Ziwei and Yang, Xueting and Wu, Rong and Zhan, Jia},
  title = {Dynamic AI Ultrasound‐Assisted Diagnosis System to Reduce Unnecessary Fine Needle Aspiration of Thyroid Nodules},
  journal = {Journal of Clinical Ultrasound},
  year = {2025},
  doi = {10.1002/jcu.24035}
}
Kostenlos starten →