Diagnostic Performance of Ultrasound‐Based Liver Fat Quantification With Reference to Magnetic Resonance Imaging Proton Density Fat Fraction and Histology
Journal of Clinical Ultrasound · 2025
DOI: 10.1002/jcu.24010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Nurullah Dag und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Radiology, Inonu University, Malatya, Türkiye. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Fatty Liver, Liver, Adipose Tissue. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Purpose
To investigate the diagnostic performance of ultrasound attenuation imaging technology (USAT) in the evaluation of hepatic steatosis using magnetic resonance imaging proton density fat fraction (MRI PDFF) and histology as reference standards.
Methods
In this single‐center, prospective study, the liver fat content of 117 potential liver donor candidates was assessed by USAT and MRI PDFF between April and August 2024. Intraoperative liver biopsy was performed in 47 liver donors. Cut‐off values of 6%, 17%, 22%, and 5%, 33%, 66% were used for mild, moderate, and severe steatosis in MRI PDFF and histology, respectively. The correlation between USAT and MRI PDFF was evaluated using Spearman's rho technique. Receiver operating characteristic (ROC) analysis was performed for the diagnostic performance of USAT, and optimal USAT cut‐off values for different grades of hepatosteatosis were obtained.
Results
There was a very strong correlation between USAT and MRI PDFF (rho = 0.933, p < 0.001). For MRI PDFF values greater than 6%, the area under the curve (AUC) was 0.97 [95% confidence interval (CI): 0.93–0.99] ( p < 0.001). USAT cut‐off values for differentiating between different grades of liver steatosis were 0.57, 0.68, and 0.76 dB/cm/MHz for mild, moderate, and severe steatosis, with sensitivities of 88.9%, 90.0%, and 86.7%, respectively. For histologically confirmed steatosis greater than 5%, the AUC was 0.94 (95% CI: 0.83–0.99) ( p < 0.001), with a cut‐off of 0.56 dB/cm/MHz for 84.6% sensitivity.
Conclusion
USAT demonstrates excellent diagnostic accuracy in both the quantification and grading of hepatic steatosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Medicine, Department of Radiology, Inonu University, Malatya, Türkiye.
- Faculty of Medicine, School of Medicine, Department of General Surgery and Liver Transplant Institute, Inonu University, Malatya, Türkiye.
- Faculty of Medicine, Department of Biostatistics and Medical Informatics, Inonu University, Malatya, Türkiye.
ORCID-Profile: Nurullah Dag, Baris Sarici, Gulnur Igci, Fatma Hilal Yagin, Sezai Yilmaz, Ramazan Kutlu
Zitieren
APA
Dag, N., Sarici, B., Igci, G., Yagin, F. H., Yilmaz, S., & Kutlu, R. (2025). Diagnostic Performance of Ultrasound‐Based Liver Fat Quantification With Reference to Magnetic Resonance Imaging Proton Density Fat Fraction and Histology. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.24010
Vancouver
Dag N, Sarici B, Igci G, Yagin FH, Yilmaz S, Kutlu R. Diagnostic Performance of Ultrasound‐Based Liver Fat Quantification With Reference to Magnetic Resonance Imaging Proton Density Fat Fraction and Histology. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.24010
BibTeX
@article{Dag2025,
author = {Dag, Nurullah and Sarici, Baris and Igci, Gulnur and Yagin, Fatma Hilal and Yilmaz, Sezai and Kutlu, Ramazan},
title = {Diagnostic Performance of Ultrasound‐Based Liver Fat Quantification With Reference to Magnetic Resonance Imaging Proton Density Fat Fraction and Histology},
journal = {Journal of Clinical Ultrasound},
year = {2025},
doi = {10.1002/jcu.24010}
}
EUVIMED