EUVIMEDEUVIMED entdecken
Crossref

Correlation of Doppler Pulmonary Artery Parameters With Gestational Age in Normal Fetuses at 20–32 Weeks

Xiaofeng Zhou, Yan Jiang, Xiaolong Zhang, Dan Xie, Mingsheng Zheng, Nan Ye, Na Shu, Shuqiang Gao iD

Journal of Clinical Ultrasound · 2025

DOI: 10.1002/jcu.23977 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Xiaofeng Zhou und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neonatology, The Affiliated Women's and Children's Hospital, School of Medicine, UESTC, Chengdu, China. Hauptthemen laut MEDLINE: Pulmonary Artery, Ultrasonography, Prenatal, Gestational Age, Ultrasonography, Doppler. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Sichuan Provincial Health Commission, Health Commission of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To measure pulmonary artery (PA) diameters and Doppler values in normal fetuses and to analyze their trends and correlations with gestational age (GA).

Methods

We took PA ultrasound measurements of normal fetuses with GAs of 20–32 weeks, including the main pulmonary artery (MPA), right pulmonary artery (RPA), and left pulmonary artery (LPA) inner diameters and MPA Doppler parameters [acceleration time (AT), ejection time (ET), AT/ET ratio, peak systolic velocity (PSV), end‐diastolic velocity (EDV), pulsatility index (PI), and resistance index (RI)]. The subjects were divided into early (20–24 weeks), middle (24–28 weeks), and late (28–32 weeks) GA groups.

Results

In total, 336 fetuses with GAs of 21 + 3 weeks to 31 + 2 weeks were included (early, n = 161; middle, n = 105; late, n = 70). The PSV, EDV, AT, ET, and PA diameters correlated positively with the GA. The correlations of the PA diameters were the strongest, and a linear regression model was obtained: MPA diameter (cm) = (−0.286 + 0.005) × GA (days).

Conclusions

The MPA, PI, RI, and AT/ET ratios are relatively stable before the GA of 32 weeks. The MPA, LPA, and RPA diameters increase with the GA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary ArteryUltrasonography, PrenatalGestational AgeUltrasonography, DopplerHumansFemalePregnancyReference ValuesAdultMaleBlood Flow Velocity

Stichwörter der Autor:innen

Dopplerfetuspulmonary artery

Autor:innen und Institutionen

  • Department of Neonatology, The Affiliated Women's and Children's Hospital, School of Medicine, UESTC, Chengdu, China.
  • Department of Ultrasound, The Affiliated Women's and Children's Hospital, School of Medicine, UESTC, Chengdu, China.

ORCID-Profile: Shuqiang Gao

Förderung

  • Sichuan Provincial Health Commission
  • Health Commission of Sichuan Province

Zitieren

APA

Zhou, X., Jiang, Y., Zhang, X., Xie, D., Zheng, M., Ye, N., Shu, N., & Gao, S. (2025). Correlation of Doppler Pulmonary Artery Parameters With Gestational Age in Normal Fetuses at 20–32 Weeks. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.23977

Vancouver

Zhou X, Jiang Y, Zhang X, Xie D, Zheng M, Ye N, et al. Correlation of Doppler Pulmonary Artery Parameters With Gestational Age in Normal Fetuses at 20–32 Weeks. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.23977

BibTeX
@article{Zhou2025,
  author = {Zhou, Xiaofeng and Jiang, Yan and Zhang, Xiaolong and Xie, Dan and Zheng, Mingsheng and Ye, Nan and Shu, Na and Gao, Shuqiang},
  title = {Correlation of Doppler Pulmonary Artery Parameters With Gestational Age in Normal Fetuses at 20–32 Weeks},
  journal = {Journal of Clinical Ultrasound},
  year = {2025},
  doi = {10.1002/jcu.23977}
}
Kostenlos starten →