EUVIMEDEUVIMED entdecken
Vergleichsstudie

Shear‐Wave Elastography Improves Diagnostic Accuracy in Chronic Kidney Disease Compared to Conventional Ultrasound

Cuiping Jiang, Shiming Zang, Qi Gao, Meili Zhao, Songwang Chen iD

Journal of Clinical Ultrasound · 2025

DOI: 10.1002/jcu.23862 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Cuiping Jiang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Nanjing First Hospital, Nanjing Medical University, Nanjing, China. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Renal Insufficiency, Chronic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Non‐invasive tests are increasingly demanded for diagnosing and prognostication of chronic kidney disease (CKD). Shear‐wave elastography (SWE), an emerging technique for measuring tissue stiffness, shows promise for distinguishing between individuals with different stages of renal fibrosis. This study aimed to compare the diagnostic accuracy of two‐dimensional SWE (2D‐SWE) and conventional ultrasound for detecting CKD, employing renal biopsy as the gold standard.

Methods

From May 2020 to October 2023, this prospective study included 30 healthy volunteers and 169 patients with CKD who had undergone 2D‐SWE and conventional ultrasound of both kidneys. Cortical and medullary stiffness, cortical pixel intensity, renal length, parenchymal and cortical thickness, interlobar artery peak systolic velocity, end‐diastolic velocity (EDV), and resistive index were measured. The diagnostic accuracy of 2D‐SWE and conventional ultrasound was compared using the receiver operating characteristic curve (ROC) and Delong test.

Results

For diagnosing CKD, the area under the ROC (AUC) of cortical stiffness (0.96 [95% CI, 0.93, 0.99]) was significantly higher than that of all conventional ultrasound parameters, including EDV (0.78 [95% CI, 0.71, 0.86]) and cortical thickness (0.74 [95% CI, 0.67, 0.80]). The sensitivity of cortical stiffness (91%) was significantly higher than that of EDV (68%) and cortical thickness (53%). No significant difference was found in the specificity of cortical stiffness (96%) compared to that of EDV (79%) and cortical thickness (100%).

Conclusion

Two‐dimensional SWE showed higher diagnostic accuracy than that of conventional ultrasound for detecting CKD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesRenal Insufficiency, ChronicHumansFemaleMaleProspective StudiesMiddle AgedAdultUltrasonographyKidneyReproducibility of ResultsSensitivity and SpecificityAged

Stichwörter der Autor:innen

chronic kidney diseaseconventional ultrasoundgray‐scale ultrasoundshear‐wave elastographyspectral doppler ultrasound

Autor:innen und Institutionen

  • Department of Ultrasound, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.
  • Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.

ORCID-Profile: Songwang Chen

Zitieren

APA

Jiang, C., Zang, S., Gao, Q., Zhao, M., & Chen, S. (2025). Shear‐Wave Elastography Improves Diagnostic Accuracy in Chronic Kidney Disease Compared to Conventional Ultrasound. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.23862

Vancouver

Jiang C, Zang S, Gao Q, Zhao M, Chen S. Shear‐Wave Elastography Improves Diagnostic Accuracy in Chronic Kidney Disease Compared to Conventional Ultrasound. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.23862

BibTeX
@article{Jiang2025,
  author = {Jiang, Cuiping and Zang, Shiming and Gao, Qi and Zhao, Meili and Chen, Songwang},
  title = {Shear‐Wave Elastography Improves Diagnostic Accuracy in Chronic Kidney Disease Compared to Conventional Ultrasound},
  journal = {Journal of Clinical Ultrasound},
  year = {2025},
  doi = {10.1002/jcu.23862}
}
Kostenlos starten →