Low placenta at the mid trimester anomaly scan—A cause for concern?

Sarika Yadav iD, Aditi Shah

Journal of Clinical Ultrasound · 2025

DOI: 10.1002/jcu.23841 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Sarika Yadav und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fetal Medicine, Fernandez Hospital, Hyderabad, India. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Pregnancy Trimester, Second, Placenta, Pregnancy Trimester, Third. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study was aimed to assess the predictive validity of internal os distance (IOD) in mid‐trimester scan for the prediction of third‐trimester low‐positioned placenta, and to define a cut‐off of IOD at which third‐trimester low‐positioned placenta could be identified, see the association of placental site (anterior/posterior), previous history of cesarean section with abnormal location of placenta in third trimester and see the maternal and neonatal outcomes.

Methods

It was a prospective cohort study of women with low‐positioned placenta (IOD < 20 mm) at mid‐trimester anomaly scan followed up in third trimester till birth. Relative risks for a low‐positioned placenta in the third‐trimester were calculated for women with posterior versus anterior, low‐lying placenta versus placenta previa and positive versus negative history of cesarean section. Multilevel likelihood ratios and corresponding ROC curves for different ranges of IOD were calculated.

Results

Women with posterior placenta had a high risk of low positioned placenta compared to anterior placenta (9.28% vs. 0.74%); RR 1.45, similarly women with placenta previa had high risk compared to low lying placenta (68.57% vs. 1.69%); RR 6.51, so did the women with previous cesarean section (9.41% vs. 5.87%); RR 1.47.

Conclusions

93.42% placenta which were low positioned in mid trimester were normally situated in third trimester. The cut‐off for IOD in anterior placenta was −40 mm and in posterior placenta was 14.3 mm. IOD measurement and interpretation seems promising.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalPregnancy Trimester, SecondPlacentaPregnancy Trimester, ThirdHumansFemalePregnancyProspective StudiesAdultPlacenta PreviaCohort StudiesPredictive Value of Tests

Stichwörter der Autor:innen

internal os distancelow‐lying placentaplacenta previaplacental migration

Autor:innen und Institutionen

  • Department of Fetal Medicine, Fernandez Hospital, Hyderabad, India.

ORCID-Profile: Sarika Yadav

Zitieren

APA

Yadav, S., & Shah, A. (2025). Low placenta at the mid trimester anomaly scan—A cause for concern?. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.23841

Vancouver

Yadav S, Shah A. Low placenta at the mid trimester anomaly scan—A cause for concern?. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.23841

BibTeX
@article{Yadav2025,
  author = {Yadav, Sarika and Shah, Aditi},
  title = {Low placenta at the mid trimester anomaly scan—A cause for concern?},
  journal = {Journal of Clinical Ultrasound},
  year = {2025},
  doi = {10.1002/jcu.23841}
}
Kostenlos starten →