Diagnostic value of Achilles tendon shear wave elastography in patients with ankylosing spondylitis: A case–control study
Journal of Clinical Ultrasound · 2024
DOI: 10.1002/jcu.23699 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2024. Verfasst von Irfan Atik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Medicine Faculty of Sivas Cumhuriyet University, Sivas, Turkey. Hauptthemen laut MEDLINE: Achilles Tendon, Elasticity Imaging Techniques, Spondylitis, Ankylosing. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Objectives
Ankylosing spondylitis (AS) can cause peripheral arthritis, tendinitis, enthesitis, and axial skeletal involvement. This study aims to determine early tendon damage by shear wave elastography (SWE) for the Achilles tendon in AS patients.
Methods
48 AS patients and 48 asymptomatic individuals were included in the study. Participants were systematically examined with B‐mode, power Doppler, and SWE using a high‐resolution linear 6–15 MHz probe. Bilateral Achilles tendon stiffness, thickness, and vascularity were evaluated. Measurements were taken from the middle third of the Achilles tendon in the sagittal plane. Difference between the two groups was evaluated with statistical methods. Receiver operating characteristic analysis was performed to test the diagnostic performance of Achilles tendon stiffness. Additionally, the Spearman correlation test examined the relationship between Achilles tendon stiffness and disease duration.
Results
The difference between the two groups regarding Achilles tendon stiffness was statistically significant ( p < 0.05). It was observed that Achilles tendon stiffness decreased in the patient group compared with the control group. The diagnostic value of Achilles tendon stiffness measured by SWE was found to be high. A negative correlation was detected between disease duration and tendon stiffness ( p < 0.05).
Conclusion
In patients diagnosed with AS, deterioration in the Achilles tendon structure was observed, and a significant decrease in tendon stiffness compared with the healthy population. It has been determined that these changes in the Achilles tendon are related to the duration of the disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Medicine Faculty of Sivas Cumhuriyet University, Sivas, Turkey.
- Division of Rheumatology, Department of Physical Medicine And Rehabilitation, Medicine Faculty of Sivas Cumhuriyet University, Sivas, Turkey.
ORCID-Profile: Irfan Atik, Seda Atik
Zitieren
APA
Atik, I., Atik, S., & Gul, E. (2024). Diagnostic value of Achilles tendon shear wave elastography in patients with ankylosing spondylitis: A case–control study. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.23699
Vancouver
Atik I, Atik S, Gul E. Diagnostic value of Achilles tendon shear wave elastography in patients with ankylosing spondylitis: A case–control study. Journal of Clinical Ultrasound. 2024. doi:10.1002/jcu.23699
BibTeX
@article{Atik2024,
author = {Atik, Irfan and Atik, Seda and Gul, Enes},
title = {Diagnostic value of Achilles tendon shear wave elastography in patients with ankylosing spondylitis: A case–control study},
journal = {Journal of Clinical Ultrasound},
year = {2024},
doi = {10.1002/jcu.23699}
}