Incidence and diagnostic performance of ultrasound for perianal abscess or fistula‐in‐ano in pediatric patients with perianal inflammation
Journal of Clinical Ultrasound · 2023-06 · 51 (5) · 819-826
DOI: 10.1002/jcu.23446 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, online erschienen am 04.03.2023. Verfasst von Takahiro Hosokawa und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Saitama Children's Medical Center, Saitama, Japan. Hauptthemen laut MEDLINE: Anus Diseases, Rectal Fistula. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
Objectives
To describe the incidence and diagnostic performance of ultrasound for perianal abscess or fistula‐in‐ano in pediatric patients with perianal inflammation.
Methods
We included 45 patients with perianal inflammation who underwent ultrasonography. To demonstrate the diagnostic performance of ultrasound for fistula‐in‐ano, a definite diagnosis of perianal abscess, and fistula‐in‐ano was determined as that proven through magnetic resonance imaging (MRI) or computed tomography (CT). The absence or presence of perianal abscess and fistula‐in‐ano on ultrasonography was recorded.
Results
Among the 45 patients, on ultrasound, perianal abscess and fistula‐in‐ano were detected in 22 (48.9%) and 30 (68.2%) patients, respectively. Nine patients had MRI or CT and a definite diagnosis of perianal abscess or fistula‐in‐ano; accuracy, negative predictive value, and positive predictive value of ultrasound for perianal abscess were 77.8% (7/9; 95% confidence interval [CI]: 40.0%–97.1%), 66.7% (2/3; 95% CI: 9.4%–99.2%), 83.3% (5/6; 95% CI: 35.9%–99.6%), and those of fistula‐in‐ano were 100% (9/9; 95% CI: 66.4%–100%), 100% (8/8; 95% CI: 63.1%–100%), and 100% (1/1; 95% CI: 2.5%–100%), respectively.
Conclusions
Perianal abscess and fistula‐in‐ano were detected by ultrasound in half of the patients with perianal inflammation. Accordingly, ultrasound has an acceptable diagnostic performance for perianal abscess and fistula‐in‐ano.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Saitama Children's Medical Center, Saitama, Japan.
- Department of Surgery, Saitama Children's Medical Center, Saitama, Japan.
- Department of Gastroenterology and Hepatology, Saitama Children's Medical Center, Saitama, Japan.
- Department of Infectious Diseases and Immunology, Saitama Children's Medical Center, Saitama, Japan.
ORCID-Profile: Takahiro Hosokawa
Zitieren
APA
Hosokawa, T., Tanami, Y., Sato, Y., Deie, K., Ishimaru, T., Hara, T., Nambu, R., Deguchi, K., Takei, H., Iwama, I., Kawashima, H., & Oguma, E. (2023). Incidence and diagnostic performance of ultrasound for perianal abscess or fistula‐in‐ano in pediatric patients with perianal inflammation. Journal of Clinical Ultrasound, 51(5), 819-826. https://doi.org/10.1002/jcu.23446
Vancouver
Hosokawa T, Tanami Y, Sato Y, Deie K, Ishimaru T, Hara T, et al. Incidence and diagnostic performance of ultrasound for perianal abscess or fistula‐in‐ano in pediatric patients with perianal inflammation. Journal of Clinical Ultrasound. 2023;51(5):819-826. doi:10.1002/jcu.23446
BibTeX
@article{Hosokawa2023,
author = {Hosokawa, Takahiro and Tanami, Yutaka and Sato, Yumiko and Deie, Kyoichi and Ishimaru, Tetsuya and Hara, Tomoko and Nambu, Ryusuke and Deguchi, Kuntaro and Takei, Haruka and Iwama, Itaru and Kawashima, Hiroshi and Oguma, Eiji},
title = {Incidence and diagnostic performance of ultrasound for perianal abscess or fistula‐in‐ano in pediatric patients with perianal inflammation},
journal = {Journal of Clinical Ultrasound},
year = {2023},
volume = {51},
number = {5},
pages = {819--826},
doi = {10.1002/jcu.23446}
}
EUVIMED