Catalase‐functionalized ZnO and graphene oxide used as electrocatalyst for the selective detection of hydrogen peroxide
Journal of Chemical Technology & Biotechnology · 2024-07 · 99 (7) · 1504-1516
DOI: 10.1002/jctb.7644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chemical Technology & Biotechnology, online erschienen am 23.04.2024. Verfasst von Swati Sharma und 5 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: Science and Engineering Research Board, Department of Science and Technology, Ministry of Science and Technology, India.
Abstract (Originalsprache)
BACKGROUND This study focuses on the fabrication of a biosensor for the electrocatalytic and selective hydrogen peroxide (H 2 O 2 ) recognition with bovine liver catalase (CAT) immobilized over a cysteine (c) modified zinc oxide nanoparticles/graphene oxide (c‐ZnO/GO) interface. The selectivity and sensitivity of the biosensor were augmented by the use of CAT and GO, respectively. The problem of CAT activity inhibition by GO was specifically solved by the incorporation of ZnO. Also, the cystine functionalization helped in better immobilization of CAT. RESULTS This unique approach was first validated with in silico computations that calculated the binding affinities to study the interactions between different components of the biosensor. The electrochemical studies confirmed the step‐by‐step modification of the sensor, where along with GO, c‐ZnO nanoparticles also showed excellent electro‐conductivity by fundamentally improving the peak currents towards H 2 O 2 . The proposed bio‐nano interface exhibited superb electrocatalytic performance and specific detection capability for H 2 O 2 across a broad linear range (0.1 to 40 μmol L −1 ), featuring a low detection limit (0.1 μmol L −1 ), as well as commendable reproducibility and storage durability. Furthermore, the biosensor yielded satisfactory outcomes for H 2 O 2 detection in milk samples. CONCLUSION Sensing performance of nano‐bio interfaces can be augmented by using the appropriate nano‐composites and their efficacy confirmed through computational techniques such as molecular docking. The biosensor can be further repurposed into a wearable device by integration with lab‐on‐a‐chip platforms. © 2024 Society of Chemical Industry (SCI).
Förderung
- Science and Engineering Research Board
- Department of Science and Technology, Ministry of Science and Technology, India
Zitieren
APA
Sharma, S., Jain, U., Rosario, W., Singh, V., Hooda, V., & Chauhan, N. (2024). Catalase‐functionalized ZnO and graphene oxide used as electrocatalyst for the selective detection of hydrogen peroxide. Journal of Chemical Technology & Biotechnology, 99(7), 1504-1516. https://doi.org/10.1002/jctb.7644
Vancouver
Sharma S, Jain U, Rosario W, Singh V, Hooda V, Chauhan N. Catalase‐functionalized ZnO and graphene oxide used as electrocatalyst for the selective detection of hydrogen peroxide. Journal of Chemical Technology & Biotechnology. 2024;99(7):1504-1516. doi:10.1002/jctb.7644
BibTeX
@article{Sharma2024,
author = {Sharma, Swati and Jain, Utkarsh and Rosario, Warren and Singh, Varshika and Hooda, Vinita and Chauhan, Nidhi},
title = {Catalase‐functionalized ZnO and graphene oxide used as electrocatalyst for the selective detection of hydrogen peroxide},
journal = {Journal of Chemical Technology & Biotechnology},
year = {2024},
volume = {99},
number = {7},
pages = {1504--1516},
doi = {10.1002/jctb.7644}
}
EUVIMED