Elucidating the trapping mechanism of underground storage for hydrogen and carbon dioxide via Geomechanical modelling: a case study of the aquifer in Malaysia
Journal of Chemical Technology & Biotechnology · 17.11.2026
DOI: 10.1002/jctb.70306 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chemical Technology & Biotechnology, online erschienen am 17.11.2026. Verfasst von Bonavian Hasiholan und 4 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND As a developed technology, underground carbon dioxide storage (UCS) can become the technical reference for the development of underground hydrogen storage (UHS). The same geological criteria can be applied to UHS to ensure its feasibility. The implemented UCS projects in Malaysia can be used as references for UHS development. This study aims to elucidate the potential of UCS and UHS in the Malaysian aquifer, focusing on trapping mechanisms, gas storage performance, gas storage behavior, and the sensitivity analysis of UHS and UCS to geomechanical properties (tensile strength, Poisson ratio, and Young's Modulus). Two CO 2 –H 2 injection strategies are used in the study, i.e., simultaneous injection and CO 2 ‐preinjection. CO 2 is injected as cushion gas with fractions of 60%, 70%, and 80%. RESULTS For cushion gas fractions of 60% and 70%, the total volume of gas injected in the preinjection strategy is higher than in the simultaneous injection. The solubility trapping in the pre‐injection strategy is lower than in the simultaneous injection strategy. The storage volume of UCS is 2.3 times more than that of UHS. UCS shows stronger solubility trapping; 35.32% of the gas has been trapped by the water in UCS at the end of the simulation, which is 16.95% higher than UHS. Furthermore, UHS has stronger residual trapping, 78.02% of gas trapped by residual trapping at the end of the simulation, which is 17.49% higher than UCS. In addition, it was found that the hydrogen equilibrium state in porous medium was achieved after 10 to 15 years of the injection, while the transition among different trapping mechanisms in UCS continued until the end of the 100‐year simulation. One of the major differences between the geomechanical and non‐geomechanical (normal) models is CO 2 dissolution in water. In the normal model, only 29.12% of CO 2 was dissolved in the end of 100 years of storage, but this increased to 35.324% in the geomechanical model. This suggests that the geomechanical effect enhances solubility trapping. CONCLUSION Overall, the findings assess a significant difference in storage capacity and trapping‐mechanism performance between UCS and UHS, which is mainly due to the solubility and the rate of conversion from mobile gas to immobile gas, and from mobile gas to dissolved gas. The effect of geomechanical property is significant in both underground carbon dioxide (CO 2 ) and hydrogen (H 2 ) storage, but its impact is larger in CO 2 storage. © 2026 Society of Chemical Industry (SCI).
Zitieren
APA
Hasiholan, B., Zhuang, T. Y., Khosravi, V., Mostafa, A. M. E., & Mukhtar, Y. (2026). Elucidating the trapping mechanism of underground storage for hydrogen and carbon dioxide via Geomechanical modelling: a case study of the aquifer in Malaysia. Journal of Chemical Technology & Biotechnology. https://doi.org/10.1002/jctb.70306
Vancouver
Hasiholan B, Zhuang TY, Khosravi V, Mostafa AME, Mukhtar Y. Elucidating the trapping mechanism of underground storage for hydrogen and carbon dioxide via Geomechanical modelling: a case study of the aquifer in Malaysia. Journal of Chemical Technology & Biotechnology. 2026. doi:10.1002/jctb.70306
BibTeX
@article{Hasiholan2026,
author = {Hasiholan, Bonavian and Zhuang, Thee Yi and Khosravi, Vahid and Mostafa, A. M. Elhassan and Mukhtar, Yasir},
title = {Elucidating the trapping mechanism of underground storage for hydrogen and carbon dioxide via Geomechanical modelling: a case study of the aquifer in Malaysia},
journal = {Journal of Chemical Technology & Biotechnology},
year = {2026},
doi = {10.1002/jctb.70306}
}