Defining reference values for body composition indices by magnetic resonance imaging in UK Biobank

Liang Dai iD, Xiao-Yan Huang, Yue-Qi Lu, Yu-Yang Liu, Cong-Ying Song, Jing-Wen Zhang, Jing Li, Yue Zhang, Ying Shan, Yu Shi

Journal of Cachexia, Sarcopenia and Muscle · 2023-04 · 14 (2) · 992-1002

DOI: 10.1002/jcsm.13181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cachexia, Sarcopenia and Muscle, online erschienen am 30.01.2023. Verfasst von Liang Dai und 9 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Research Academy, Peking University Shenzhen Hospital, Peking University, Shenzhen, Guangdong, China. Hauptthemen laut MEDLINE: Biological Specimen Banks, Body Composition. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Medical Research Council, Scientific Research Foundation of Peking University Shenzhen Hospital, San-Ming Project of Medicine, Shenzhen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) is the gold standard for evaluating body composition. However, the reference ranges have not been established.

Methods

Three lean tissue and seven adipose tissue parameters based on MRI data from the UK Biobank were used in this study. Participants with European ancestry and data on at least one parameter were screened. Age‐ and sex‐specific percentile curves were generated using the lambda–mu–sigma method. Three levels of reference ranges were provided, which were equivalent to the mean ± 1 standard deviation ( SD ), 2 SD s and 2.5 SD s.

Results

The final analysis set for each parameter ranged from 4842 to 14 148 participants (53.4%–56.6% women) with a median age of 61. For lean tissue parameters, compared with those at age 45, the median total lean tissue volume and total thigh fat‐free muscle volume at age 70 were 2.83 and 1.73 L, and 3.02 and 1.51 L lower in men and women, respectively. The median weight‐to‐muscle ratios at age 45 were 0.51 and 0.83 kg/L lower compared with those at age 70 in men and women, respectively. Adipose tissue parameters showed inconsistent differences. In men, the median muscle fat infiltration, visceral adipose tissue (VAT) volume, total abdominal adipose tissue index and abdominal fat ratio were 1.48%, 0.32 L, 0.08 L/m 2 and 0.4 higher, and the median abdominal subcutaneous adipose tissue (ASAT) volume and total adipose tissue volume were 0.47 and 0.41 L lower, respectively, at age 70 than at age 45. The median total trunk fat volume was approximately 9.53 L at all ages. In women, the median muscle fat infiltration and VAT volume were 1.68% and 0.76 L higher, respectively, at age 70 than at age 45. The median ASAT volume, total adipose tissue volume, total trunk fat volume, total abdominal adipose tissue index and abdominal fat ratio were 0.35 L, 0.78 L, 1.12 L, 0.49 L/m 2 and 0.06 higher, respectively, at age 60 than at age 45. The medians of the former three parameters were 0.33 L, 0.14 L and 0.20 L lower, at age 70 than at age 60. The medians of the latter two parameters were approximately 3.64 L/m 2 and 0.55 at ages between 60 and 70.

Conclusions

We have established reference ranges for MRI‐measured body composition parameters in a large community‐dwelling population. These findings provide a more accurate assessment of abnormal adipose and muscle conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biological Specimen BanksBody CompositionMaleHumansFemaleMiddle AgedAgedReference ValuesMuscle, SkeletalMagnetic Resonance ImagingUnited Kingdom

Stichwörter der Autor:innen

Abdominal body compositionLambda-mu-sigma methodMagnetic resonance imagingReference ranges

Autor:innen und Institutionen

  • Clinical Research Academy, Peking University Shenzhen Hospital, Peking University, Shenzhen, Guangdong, China.
  • Renal Division, Peking University Shenzhen Hospital, Peking University, Shenzhen, China.
  • BGI-Shenzhen, Shenzhen, China.
  • College of Life Sciences, University of Chinese Academy of Sciences, Beijing, China.
  • Department of Ultrasound, Peking University Shenzhen Hospital, Peking University, Shenzhen, Guangdong, China.

ORCID-Profile: Liang Dai

Förderung

  • Medical Research Council
  • Scientific Research Foundation of Peking University Shenzhen Hospital
  • San-Ming Project of Medicine, Shenzhen
  • Shenzhen Science and Technology Innovation Commission
  • General Program for Clinical Research at Peking University Shenzhen Hospital
  • National Natural Science Foundation of China
  • Sanming Project of Medicine in Shenzhen
  • Science, Technology and Innovation Commission of Shenzhen Municipality

Zitieren

APA

Dai, L., Huang, X. Y., Lu, Y. Q., Liu, Y. Y., Song, C. Y., Zhang, J. W., Li, J., Zhang, Y., Shan, Y., & Shi, Y. (2023). Defining reference values for body composition indices by magnetic resonance imaging in UK Biobank. Journal of Cachexia, Sarcopenia and Muscle, 14(2), 992-1002. https://doi.org/10.1002/jcsm.13181

Vancouver

Dai L, Huang XY, Lu YQ, Liu YY, Song CY, Zhang JW, et al. Defining reference values for body composition indices by magnetic resonance imaging in UK Biobank. Journal of Cachexia, Sarcopenia and Muscle. 2023;14(2):992-1002. doi:10.1002/jcsm.13181

BibTeX
@article{Dai2023,
  author = {Dai, Liang and Huang, Xiao-Yan and Lu, Yue-Qi and Liu, Yu-Yang and Song, Cong-Ying and Zhang, Jing-Wen and Li, Jing and Zhang, Yue and Shan, Ying and Shi, Yu},
  title = {Defining reference values for body composition indices by magnetic resonance imaging in UK Biobank},
  journal = {Journal of Cachexia, Sarcopenia and Muscle},
  year = {2023},
  volume = {14},
  number = {2},
  pages = {992--1002},
  doi = {10.1002/jcsm.13181}
}
Kostenlos starten →