Is Geenius HCV Supplemental Assay an Alternative to HCV Confirmatory Western Blot INNO ‐ LIA HCV Score in Repeatedly Reactive Blood Donations After First Line Screening?
Journal of Clinical Laboratory Analysis · 2026-11 · 40 (21)
DOI: 10.1002/jcla.70367 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Laboratory Analysis, online erschienen am 09.10.2026. Verfasst von Zorana P Kozić und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Transfusiology and Haemobiology, Military Medical Academy, Belgrade, Serbia. Hauptthemen laut MEDLINE: Hepatitis C Antibodies, Blood Donors, Blotting, Western, Hepatitis C. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The Ministry of Science, Technological Development and Innovation of the Republic of Serbia.
Abstract (Originalsprache)
Background
The objective of this study is to evaluate whether the rapid lateral flow immunochromatography Geenius HCV Supplemental Assay (ICH) can serve as an alternative to INNO‐LIA HCV Score Confirmatory western blot (WB) assay in a population of blood donors.
Methods
Sera of 60 blood donors, anti‐HCV antibodies repeatedly reactive after first line screening with Architect anti‐HCV chemiluminescent immunoassay, (ABBOTT, Wiesbaden, Germany) (ICL) were evaluated for anti‐HCV antibodies with Geenius HCV Supplemental assay (Bio‐Rad. Marnes‐la‐Coquette—France) (ICH) and Inno‐LIA HCV Score (Inogenetics NV. Gent. Belgium) (Inno‐LIA WB). The level of agreement between ICH and WB results was determined by kappa statistics.
Results
Out of 60 samples identified as anti‐HCV antibodies repeatedly reactive by ICL, ICH identified 32% samples as reactive and 2% as indeterminate. WB identified 35% samples as positive and 20% as indeterminate. Kappa analysis detected moderate agreement between ICH and WB in detecting anti‐HCV antibodies (kappa = 0.60). Moderate to almost very good agreement is acknowledged between ICH and WB in reactivity with individual HCV antigens.
Conclusion
Given the limited number of samples analyzed in this study we can summarize that Geenius HCV Supplemental and Inno‐LIA WB assays are comparable pertaining to anti‐HCV positive samples, but with discrepancy in results occurring in the area of samples classified with WB assay as indeterminate. However, there is very good agreement between Inno‐LIA WB and Geenius ICH positivity/reactivity with individual HCV antigens. Our findings indicate that Geenius ICH Supplemental test cannot replace anti‐HCV Inno‐LIA WB in confirming anti‐HCV antibodies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute for Transfusiology and Haemobiology, Military Medical Academy, Belgrade, Serbia.
- Institute for Medical Research, National Institute of Republic of Serbia, University of Belgrade, Belgrade, Serbia.
- Faculty of Medicine, Military Medical Academy, University of Defence, Belgrade, Serbia.
ORCID-Profile: Zorana P Kozić, Irina S Maslovarić, Ivana T Drvenica, Marijana V Kovačić, Dragana C Marković, Vesna Lj Ilić, Dušan D Vučetić
Förderung
- The Ministry of Science, Technological Development and Innovation of the Republic of Serbia
Zitieren
APA
Kozić, Z. P., Maslovarić, I. S., Drvenica, I. T., Kovačić, M. V., Marković, D. C., Ilić, V. L., & Vučetić, D. D. (2026). Is Geenius HCV Supplemental Assay an Alternative to HCV Confirmatory Western Blot INNO ‐ LIA HCV Score in Repeatedly Reactive Blood Donations After First Line Screening?. Journal of Clinical Laboratory Analysis, 40(21). https://doi.org/10.1002/jcla.70367
Vancouver
Kozić ZP, Maslovarić IS, Drvenica IT, Kovačić MV, Marković DC, Ilić VL, et al. Is Geenius HCV Supplemental Assay an Alternative to HCV Confirmatory Western Blot INNO ‐ LIA HCV Score in Repeatedly Reactive Blood Donations After First Line Screening?. Journal of Clinical Laboratory Analysis. 2026;40(21). doi:10.1002/jcla.70367
BibTeX
@article{Kozi2026,
author = {Kozić, Zorana P and Maslovarić, Irina S and Drvenica, Ivana T and Kovačić, Marijana V and Marković, Dragana C and Ilić, Vesna Lj and Vučetić, Dušan D},
title = {Is Geenius HCV Supplemental Assay an Alternative to HCV Confirmatory Western Blot INNO ‐ LIA HCV Score in Repeatedly Reactive Blood Donations After First Line Screening?},
journal = {Journal of Clinical Laboratory Analysis},
year = {2026},
volume = {40},
number = {21},
doi = {10.1002/jcla.70367}
}
EUVIMED