EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Duplex Recombinase Polymerase Amplification‐Lateral Flow Assay for Rapid Visual Detection of Critical Antibiotic Resistance Genes in Escherichia coli and Klebsiella pneumoniae From Positive Blood Cultures

Variya Nemidkanam iD, Pattamaporn Deechart iD, Nuntaree Chaichanawongsaroj iD

Journal of Clinical Laboratory Analysis · 2026-07 · 40 (14)

DOI: 10.1002/jcla.70278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Laboratory Analysis, online erschienen am 04.06.2026. Verfasst von Variya Nemidkanam und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Transfusion Medicine and Clinical Microbiology, Faculty of Allied Health Sciences, Center of Excellence for Innovative Diagnosis of Ant…. Hauptthemen laut MEDLINE: Klebsiella pneumoniae, Escherichia coli, Nucleic Acid Amplification Techniques, Drug Resistance, Bacterial. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Thailand Science Research and Innovation Fund, Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Bloodstream infections (BSIs) caused by multidrug‐resistant bacteria (MDR) are a leading cause of mortality and morbidity among hospitalized patients. Extended‐Spectrum Beta‐Lactamase (ESBL), carbapenem‐resistant Enterobacterales (CRE), and colistin resistance are critically important antibiotic‐resistant bacteria. The rapid identification of these critical antibiotic resistance genes from positive blood cultures is essential for accelerating the diagnostic turnaround time, enabling early therapy, and supporting effective antibiotic stewardship programs.

Methods

Recombinase Polymerase Amplification (RPA) integrated with an in‐house Lateral Flow Assay (LFA) for duplex detection of bla CTX‐M / mcr‐1 and bla oxa‐48‐like / bla NDM was established in this study. 5′ modified primers compatible with those immobilized antibodies on LFA were designed. The primer concentrations, temperature, and time were optimized at 0.2–0.6 μM, 36°C–39°C, and 20–30 min, respectively. The duplex RPA amplicons were diluted in buffer and visually detected on in‐house lateral flow strips within 10–15 min. The limit of detection (LOD), specificity, and method validation were evaluated.

Results

The optimal primer concentrations of bla CTX‐M / mcr‐1 (0.35 μM/0.35 μM) and bla oxa‐48‐like / bla NDM (0.2 μM/0.6 μM) provided balanced signal intensities for all target genes at 37°C–38°C within 25 min. The LOD across incubation time of 0–8 h was determined as 10 7 –10 2 CFU/mL. No cross‐reactivity was observed with other common Gram‐negative pathogens. Sensitivity and specificity of duplex RPA‐LFA for bla CTX‐M , mcr‐1 , and bla oxa‐48‐like / bla NDM detection were 85.71%–98.28% and 93.62%–100%. The accuracy was 93.33%–96.13%.

Conclusion

This developed duplex RPA‐LFA assay is well‐suited for rapid screening in positive blood cultures, providing a cost‐effective tool for the treatment, surveillance, and control of MDR in critical infections.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Klebsiella pneumoniaeEscherichia coliNucleic Acid Amplification TechniquesDrug Resistance, BacterialPolymerase Chain ReactionHumansRecombinasesBlood Culturebeta-LactamasesRapid Diagnostic TestsLimit of DetectionSensitivity and SpecificityAnti-Bacterial Agents

Stichwörter der Autor:innen

Escherichia coliKlebsiella pneumoniaebla CTX‐Mbla NDMbla oxa‐48‐likemcr‐1lateral flow assayrecombinase polymerase amplification

Substanzen

Recombinasesbeta-LactamasesAnti-Bacterial Agents

Autor:innen und Institutionen

  • Department of Transfusion Medicine and Clinical Microbiology, Faculty of Allied Health Sciences, Center of Excellence for Innovative Diagnosis of Antimicrobial Resistance, Chulalongkorn University, Bangkok, Thailand.

ORCID-Profile: Variya Nemidkanam, Pattamaporn Deechart, Nuntaree Chaichanawongsaroj

Förderung

  • Thailand Science Research and Innovation Fund, Chulalongkorn University

Zitieren

APA

Nemidkanam, V., Deechart, P., & Chaichanawongsaroj, N. (2026). Duplex Recombinase Polymerase Amplification‐Lateral Flow Assay for Rapid Visual Detection of Critical Antibiotic Resistance Genes in Escherichia coli and Klebsiella pneumoniae From Positive Blood Cultures. Journal of Clinical Laboratory Analysis, 40(14). https://doi.org/10.1002/jcla.70278

Vancouver

Nemidkanam V, Deechart P, Chaichanawongsaroj N. Duplex Recombinase Polymerase Amplification‐Lateral Flow Assay for Rapid Visual Detection of Critical Antibiotic Resistance Genes in Escherichia coli and Klebsiella pneumoniae From Positive Blood Cultures. Journal of Clinical Laboratory Analysis. 2026;40(14). doi:10.1002/jcla.70278

BibTeX
@article{Nemidkanam2026,
  author = {Nemidkanam, Variya and Deechart, Pattamaporn and Chaichanawongsaroj, Nuntaree},
  title = {Duplex Recombinase Polymerase Amplification‐Lateral Flow Assay for Rapid Visual Detection of Critical Antibiotic Resistance Genes in Escherichia coli and Klebsiella pneumoniae From Positive Blood Cultures},
  journal = {Journal of Clinical Laboratory Analysis},
  year = {2026},
  volume = {40},
  number = {14},
  doi = {10.1002/jcla.70278}
}
Kostenlos starten →