Quantitative Analysis of DNA Double‐Strand Breaks in Genomic DNA Using Standard Curve Method
Journal of Clinical Laboratory Analysis · 2025
DOI: 10.1002/jcla.70123 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Laboratory Analysis, 2025. Verfasst von Lihuang Guo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, the Third Xiangya Hospital, Central South University, Changsha, China. Hauptthemen laut MEDLINE: DNA Breaks, Double-Stranded, DNA, Real-Time Polymerase Chain Reaction. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wu Jieping Medical Foundation.
Abstract (Originalsprache)
Background
DNA double‐strand breaks (DSBs) are the most lethal and dangerous type of lesions with significant implications for both cellular function and organismal health. The number of DSBs (N DSBs ) across the genome reflects DNA damage severity. However, current quantification methods mainly rely on next‐generation sequencing, which is laborious and expensive. This study aims to provide a simple, low‐cost, and high‐throughput standard curve‐based method for quantifying genome‐wide DSBs.
Method
Genomic DNA from human, mouse, Arabidopsis , Saccharomyces cerevisiae , and Escherichia coli was digested by seven blunt‐end restriction enzymes to generate DSB standards. Theoretical N DSBs for each standard were calculated based on restriction site frequency. Ligation‐mediated quantitative PCR (LM‐qPCR) was performed to obtain the Ct values, which were plotted against log‐transformed N DSBs to construct standard curves. Method reliability was assessed by comparing results with neutral single‐cell gel electrophoresis and γ‐H2AX flow cytometry.
Results
All genomes were successfully digested by seven blunt‐end restriction enzymes to produce standard DSB fragments. Standard curves demonstrated high linearity ( R 2 > 0.95), with intra‐ and inter‐assay coefficients of variation of 1.101% and 2.528%, respectively. The detection limit was below 100 DSBs. Quantification results strongly correlated with traditional DSB detection methods (| r | > 0.9).
Conclusion
This standard curve‐based method enables accurate, reproducible quantification of genome‐wide DSBs in various organisms. It is simple, low‐cost, and easily standardized, offering a promising tool for applications in genotoxicity testing, environmental exposure monitoring, and DNA damage research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, the Third Xiangya Hospital, Central South University, Changsha, China.
- Department of Laboratory Medicine, Xiangya School of Medicine, Central South University, Changsha, China.
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, Shenzhen, China.
ORCID-Profile: Lihuang Guo
Förderung
- Wu Jieping Medical Foundation
Zitieren
APA
Guo, L., Dai, H., Li, J., Li, C., Huang, Y., & Xu, K. (2025). Quantitative Analysis of DNA Double‐Strand Breaks in Genomic DNA Using Standard Curve Method. Journal of Clinical Laboratory Analysis. https://doi.org/10.1002/jcla.70123
Vancouver
Guo L, Dai H, Li J, Li C, Huang Y, Xu K. Quantitative Analysis of DNA Double‐Strand Breaks in Genomic DNA Using Standard Curve Method. Journal of Clinical Laboratory Analysis. 2025. doi:10.1002/jcla.70123
BibTeX
@article{Guo2025,
author = {Guo, Lihuang and Dai, Hanying and Li, Jiancheng and Li, Chenwei and Huang, Yue and Xu, Keqian},
title = {Quantitative Analysis of DNA Double‐Strand Breaks in Genomic DNA Using Standard Curve Method},
journal = {Journal of Clinical Laboratory Analysis},
year = {2025},
doi = {10.1002/jcla.70123}
}
EUVIMED