EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Accurate method for value assignment of carcinoembryonic antigen reference materials

Rui Zhang iD, Zhenzhen Xu, Rui Zhao iD, Wenxuan Fu, Yichuan Song, Qingtao Wang iD, Yuhong Yue

Journal of Clinical Laboratory Analysis · 2023-06 · 37 (11-12)

DOI: 10.1002/jcla.24936 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Laboratory Analysis, online erschienen am 03.07.2023. Verfasst von Rui Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Beijing Chao-yang Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Clinical Laboratory Services. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Beijing Municipal Administration of Hospitals Clinical Medicine Development of Special Funding Support.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In this study, we explored the commutability of reference materials (RMs) for carcinoembryonic antigen (CEA), selected the appropriate diluent matrix of the first International Reference Preparation (IRP) 73/601 of the World Health Organization (WHO 73/601) for CEA, and improved the comparability of CEA measurement results among different assay systems.

Methods

Forty serum samples were divided into five aliquots. WHO 73/601 was diluted into nine concentrations using five diluents with different components, and the candidate RMs for CEA at five concentrations (C1–C5) were prepared by the Beijing Clinical Laboratory Center (BCCL). The samples were analyzed via five automated CEA immunoassays.

Results

Carcinoembryonic antigen candidate RMs were commutable among all immunoassays based on the CLSI approach and among 7 of 10 assay combinations based on the IFCC approach. WHO 73/601 diluted in phosphate‐buffered saline (PBS) was commutable among all assays based on the CLSI approach and among 5 of 10 pairwise comparisons based on the IFCC approach with correction of bias at diluted concentrations, except for the lowest concentration, which had the smallest variation among systems. The median percentage biases among assays were decreased after calibration.

Conclusion

The BCCL candidate RMs (C2–C5) for CEA were commutable among all immunoassays. WHO 73/601 RMs diluted in a PBS buffer matrix were selected as common calibrators for five immunoassays, which reduced bias, thereby effectively improving the harmonization of CEA detection; therefore, they could be used to assign values to CEA candidate RMs developed by BCCL. Our findings promote the harmonization of CEA detection in immunoassays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carcinoembryonic AntigenClinical Laboratory ServicesHumansImmunoassayLaboratoriesLaboratories, ClinicalReference Standards

Stichwörter der Autor:innen

carcinoembryonic antigencommutabilitycomparabilityreference material

Substanzen

Carcinoembryonic Antigen

Autor:innen und Institutionen

  • Department of Clinical Laboratory, Beijing Chao-yang Hospital, Capital Medical University, Beijing, China.
  • Beijing Center for Clinical Laboratories, Beijing, China.

ORCID-Profile: Rui Zhang, Rui Zhao, Qingtao Wang

Förderung

  • Beijing Municipal Administration of Hospitals Clinical Medicine Development of Special Funding Support

Zitieren

APA

Zhang, R., Xu, Z., Zhao, R., Fu, W., Song, Y., Wang, Q., & Yue, Y. (2023). Accurate method for value assignment of carcinoembryonic antigen reference materials. Journal of Clinical Laboratory Analysis, 37(11-12). https://doi.org/10.1002/jcla.24936

Vancouver

Zhang R, Xu Z, Zhao R, Fu W, Song Y, Wang Q, et al. Accurate method for value assignment of carcinoembryonic antigen reference materials. Journal of Clinical Laboratory Analysis. 2023;37(11-12). doi:10.1002/jcla.24936

BibTeX
@article{Zhang2023,
  author = {Zhang, Rui and Xu, Zhenzhen and Zhao, Rui and Fu, Wenxuan and Song, Yichuan and Wang, Qingtao and Yue, Yuhong},
  title = {Accurate method for value assignment of carcinoembryonic antigen reference materials},
  journal = {Journal of Clinical Laboratory Analysis},
  year = {2023},
  volume = {37},
  number = {11-12},
  doi = {10.1002/jcla.24936}
}
Kostenlos starten →