EUVIMEDEUVIMED entdecken
Crossref

Non‐enzymatic hydrogen peroxide sensor based on palladium‐decorated poly(thionine) modified glassy carbon electrode

Mutlu Sönmez Çelebi, Songül Kırlak Kara

Journal of the Chinese Chemical Society · 2024-05 · 71 (5) · 482-492

DOI: 10.1002/jccs.202400009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Chinese Chemical Society, 2024-04. Verfasst von Mutlu Sönmez Çelebi und 1 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glassy carbon electrode was modified with palladium‐decorated conducting poly(thionine) film to develop a simple, cost‐effective, and fast amperometric sensor for the detection of H 2 O 2 . Conducting PTH film served as a porous and stable support matrix for even distribution of the Pd nanomaterials. In order to get the maximum performance from the modified electrode system, experimental conditions were optimized using chronoamperometry. The Pd/PTH@GCE electrode showed maximum performance in buffer solution at pH = 7.5 meaning it is suitable for the detection of H 2 O 2 at physiological pH (7.4). Scanning Electron Microscopy was performed for physical characterization of the modified electrodes using pencil graphite electrodes. The active surface area for Pd/PTH‐modified GCE was calculated as 1.103 cm 2 . The linear concentration range was determined as 0.2–7.0 mM and its sensitivity was determined as 40.0 μA mM −1 . The detection limit (LOD) of the sensor was calculated as 12.3 μM with a signal/noise ratio of 3.

Zitieren

APA

Çelebi, M. S., & Kara, S. K. (2024). Non‐enzymatic hydrogen peroxide sensor based on palladium‐decorated poly(thionine) modified glassy carbon electrode. Journal of the Chinese Chemical Society, 71(5), 482-492. https://doi.org/10.1002/jccs.202400009

Vancouver

Çelebi MS, Kara SK. Non‐enzymatic hydrogen peroxide sensor based on palladium‐decorated poly(thionine) modified glassy carbon electrode. Journal of the Chinese Chemical Society. 2024;71(5):482-492. doi:10.1002/jccs.202400009

BibTeX
@article{elebi2024,
  author = {Çelebi, Mutlu Sönmez and Kara, Songül Kırlak},
  title = {Non‐enzymatic hydrogen peroxide sensor based on palladium‐decorated poly(thionine) modified glassy carbon electrode},
  journal = {Journal of the Chinese Chemical Society},
  year = {2024},
  volume = {71},
  number = {5},
  pages = {482--492},
  doi = {10.1002/jccs.202400009}
}
Kostenlos starten →