Development and test of highly accurate endpoint free energy methods. 2: Prediction of logarithm of n ‐octanol–water partition coefficient ( logP ) for druglike molecules using MM‐PBSA method
Journal of Computational Chemistry · 15.05.2023 · 44 (13) · 1300-1311
DOI: 10.1002/jcc.27086 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Computational Chemistry, online erschienen am 23.02.2023. Verfasst von Yuchen Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Sciences and Computational Chemical Genomics Screening Center, School of Pharmacy, University of Pittsburgh, Pittsburgh,…. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, National Science Foundation, National Institute of General Medical Sciences.
Abstract (Originalsprache)
The logarithm of n ‐octanol–water partition coefficient (logP) is frequently used as an indicator of lipophilicity in drug discovery, which has substantial impacts on the absorption, distribution, metabolism, excretion, and toxicity of a drug candidate. Considering that the experimental measurement of the property is costly and time‐consuming, it is of great importance to develop reliable prediction models for logP. In this study, we developed a transfer free energy‐based logP prediction model‐FElogP. FElogP is based on the simple principle that logP is determined by the free energy change of transferring a molecule from water to n ‐octanol. The underlying physical method to calculate transfer free energy is the molecular mechanics‐Poisson Boltzmann surface area (MM‐PBSA), thus this method is named as free energy‐based logP (FElogP). The superiority of FElogP model was validated by a large set of 707 structurally diverse molecules in the ZINC database for which the measurement was of high quality. Encouragingly, FElogP outperformed several commonly‐used QSPR or machine learning‐based logP models, as well as some continuum solvation model‐based methods. The root‐mean‐square error (RMSE) and Pearson correlation coefficient (R) between the predicted and measured values are 0.91 log units and 0.71, respectively, while the runner‐up, the logP model implemented in OpenBabel had an RMSE of 1.13 log units and R of 0.67. Given the fact that FElogP was not parameterized against experimental logP directly, its excellent performance is likely to be expanded to arbitrary organic molecules covered by the general AMBER force fields.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pharmaceutical Sciences and Computational Chemical Genomics Screening Center, School of Pharmacy, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
- College of Pharmaceutical Sciences, Zhejiang University, Zhejiang, China.
ORCID-Profile: Junmei Wang
Förderung
- NIGMS NIH HHS
- National Science Foundation
- National Institute of General Medical Sciences
Zitieren
APA
Sun, Y., Hou, T., He, X., Man, V. H., & Wang, J. (2023). Development and test of highly accurate endpoint free energy methods. 2: Prediction of logarithm of n ‐octanol–water partition coefficient ( logP ) for druglike molecules using MM‐PBSA method. Journal of Computational Chemistry, 44(13), 1300-1311. https://doi.org/10.1002/jcc.27086
Vancouver
Sun Y, Hou T, He X, Man VH, Wang J. Development and test of highly accurate endpoint free energy methods. 2: Prediction of logarithm of n ‐octanol–water partition coefficient ( logP ) for druglike molecules using MM‐PBSA method. Journal of Computational Chemistry. 2023;44(13):1300-1311. doi:10.1002/jcc.27086
BibTeX
@article{Sun2023,
author = {Sun, Yuchen and Hou, Tingjun and He, Xibing and Man, Viet Hoang and Wang, Junmei},
title = {Development and test of highly accurate endpoint free energy methods. 2: Prediction of logarithm of n ‐octanol–water partition coefficient ( logP ) for druglike molecules using MM‐PBSA method},
journal = {Journal of Computational Chemistry},
year = {2023},
volume = {44},
number = {13},
pages = {1300--1311},
doi = {10.1002/jcc.27086}
}
EUVIMED