Constitutive Modeling of Degradation‐Induced Mechanical Behavior in Commercial Polydioxanone for Implantable Devices
Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2026-11 · 114 (11)
DOI: 10.1002/jbm.b.70175 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, online erschienen am 30.10.2026. Verfasst von Vito Burgio und 5 weiteren Autor:innen. Beteiligte Einrichtung: BIO-MAterials and STructures Laboratory (BIOMAST Lab), Department of Structural, Geotechnical and Building Engineering, Politecnico di Torino, Torino…. Hauptthemen laut MEDLINE: Polydioxanone, Materials Testing, Prostheses and Implants. Die Arbeit nennt 31 Literaturangaben. Gefördert von: EUREKA! venture SGR.
Abstract (Originalsprache)
In this study, the mechanical behavior of a commercially available polydioxanone (RESOMER X 206S, Evonik) and its evolution under in vitro degradation were investigated through combined experimental and constitutive modeling approaches. Tensile tests were performed on injection‐molded dog‐bone specimens at multiple time points during immersion in phosphate‐buffered saline (PBS) at 37°C for up to 4 weeks. Experimentally, the material exhibited a distinct transition from ductile to brittle behavior after approximately 3 weeks of degradation. Based on these findings, an extension of the Three Network Model (TNM), termed TNM for Degradation (TNMfD), was developed and validated to predict the degradation‐dependent mechanical response of biodegradable polymers under nearly incompressible conditions. The model parameters of the TNM were initially identified to accurately reproduce the mechanical response of PDO before degradation, establishing baseline values for degradation‐insensitive parameters and reference points for degradation‐dependent ones. Subsequently, two formulations of the hydrolytic damage parameter were evaluated within the TNMfD framework. Both formulations successfully captured the degradation‐induced changes in mechanical behavior, demonstrating good agreement with experimental data. The proposed TNMfD provides a robust, efficient numerical tool for the in silico assessment and design of biodegradable polymer‐based medical devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- BIO-MAterials and STructures Laboratory (BIOMAST Lab), Department of Structural, Geotechnical and Building Engineering, Politecnico di Torino, Torino, Italy.
ORCID-Profile: Vito Burgio, Paola Antonaci, Cecilia Surace
Förderung
- EUREKA! venture SGR
Zitieren
APA
Burgio, V., Di Giacinti, M., Rodriguez Reinoso, M., Tuveri, V., Antonaci, P., & Surace, C. (2026). Constitutive Modeling of Degradation‐Induced Mechanical Behavior in Commercial Polydioxanone for Implantable Devices. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 114(11). https://doi.org/10.1002/jbm.b.70175
Vancouver
Burgio V, Di Giacinti M, Rodriguez Reinoso M, Tuveri V, Antonaci P, Surace C. Constitutive Modeling of Degradation‐Induced Mechanical Behavior in Commercial Polydioxanone for Implantable Devices. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2026;114(11). doi:10.1002/jbm.b.70175
BibTeX
@article{Burgio2026,
author = {Burgio, Vito and Di Giacinti, Martina and Rodriguez Reinoso, Mariana and Tuveri, Valentina and Antonaci, Paola and Surace, Cecilia},
title = {Constitutive Modeling of Degradation‐Induced Mechanical Behavior in Commercial Polydioxanone for Implantable Devices},
journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
year = {2026},
volume = {114},
number = {11},
doi = {10.1002/jbm.b.70175}
}
EUVIMED