Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis
Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2026-03 · 114 (3)
DOI: 10.1002/jbm.b.70040 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, online erschienen am 26.03.2026. Verfasst von Gregg Suaning und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, The University of Sydney, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Neural Prostheses, Prostheses and Implants. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg.
Abstract (Originalsprache)
Neuroprostheses have contributed extensively to humankind's capacity to treat disease and injury. Hearing loss is routinely overcome; pain is controlled; and myriad neurological, sensory, motor, and psychological disorders are managed through interventions involving neuromodulation. Fabrication of active implantable medical devices (AIMDs) often relies on highly skilled operators, leading to high costs, reliability challenges, and limitations to further device miniaturization and manufacturing output. Extending AIMD benefits to other disorders may also require a substantial increase in the number of stimulation or recording channels, exceeding the boundaries of existing fabrication techniques and human dexterity. In one‐to‐one correspondence, electrical signals must transition between the biological environment and a controlled atmosphere suitable for protecting active electronics—e.g., electrodes interfaced to excitable tissue must ultimately connect to a circuit node, each sensitive to corrosion or shorting when exposed to moisture and ions. Protection is typically achieved by hermetic encapsulation, with each signal crossing the hermetic barrier via a conductive pathway ( feedthrough ). As the quantity of signals increases, so does the complexity of the encapsulation. Herein, we describe a robust hermetic encapsulation approach with feedthrough densities of around 250 contacts/cm 2 and establishment of interconnections to each feedthrough in an all‐at‐once fashion. The resulting interfaces offer impedances < 5 mΩ between a connection pad of the electronics to the electrode and bond strengths ~10 MPa. An illustrative example is presented as a visual neuroprosthesis for retinal dystrophies with 99 channels of electrical stimulation and associated power and communication interfaces—a device that we call the Phoenix 99 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, The University of Sydney, Sydney, New South Wales, Australia.
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Freiburg Institute for Advanced Studies (FRIAS), The University of Freiburg, Freiburg, Germany.
- Indigo Diabetes N.V, Ghent, Belgium.
- Institute for Micro Integration (IFM), University of Stuttgart, Stuttgart, Germany.
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia.
ORCID-Profile: Gregg Suaning, Juan S Ordonez, Thomas Guenther, Samuel Eggenberger, Orsolya Kékesi, Anne Vanhoestenberghe, Nigel H Lovell, Thomas Stieglitz
Förderung
- Australian Research Council
- Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg
Zitieren
APA
Suaning, G., Ordonez, J. S., Guenther, T., Eggenberger, S., Kékesi, O., Vanhoestenberghe, A., Lovell, N. H., & Stieglitz, T. (2026). Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 114(3). https://doi.org/10.1002/jbm.b.70040
Vancouver
Suaning G, Ordonez JS, Guenther T, Eggenberger S, Kékesi O, Vanhoestenberghe A, et al. Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2026;114(3). doi:10.1002/jbm.b.70040
BibTeX
@article{Suaning2026,
author = {Suaning, Gregg and Ordonez, Juan S and Guenther, Thomas and Eggenberger, Samuel and Kékesi, Orsolya and Vanhoestenberghe, Anne and Lovell, Nigel H and Stieglitz, Thomas},
title = {Establishment of High Channel‐Count Packaging in Active Implantable Medical Devices for Neuroprosthesis},
journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
year = {2026},
volume = {114},
number = {3},
doi = {10.1002/jbm.b.70040}
}
EUVIMED