EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

In Vivo Evaluation of ZnAg3—A New Bioabsorbable Material in Fracture Treatment Compared to Biodegradable Mg Alloys

Maria Roesner, Anna Baghnavi, Bianca Riedel, Adalbert Kovacs, Moritz Benner, Roland Barkhoff, Hagen Schmal, Eva Johanna Kubosch, Michael Seidenstuecker iD

Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2025-09 · 113 (9)

DOI: 10.1002/jbm.b.35647 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, online erschienen am 28.08.2025. Verfasst von Maria Roesner und 8 weiteren Autor:innen. Beteiligte Einrichtung: G.E.R.N. Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Fre…. Hauptthemen laut MEDLINE: Alloys, Absorbable Implants, Zinc, Magnesium. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Wirtschaft und Energie.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Permanent implants, which are primarily used to treat fractures, are either removed during a subsequent procedure or remain in the body after being surgically inserted. Bioabsorbable implants are designed to be reabsorbed by the body, minimizing the risk of chronic infections or foreign body reactions. The qualification of a novel zinc‐silver alloy containing 3.3 wt% silver (ZnAg3) as a bioabsorbable implant was investigated in this in vivo study on New Zealand white rabbits. The osteointegration of ZnAg3 pins and MAGNEZIX pins, which served as controls, was evaluated histomorphometrically and histologically at 4, 8, and 16‐week intervals. The implant area and the osteoid area were measured in order to assess the degradation of the material as well as the bone formation. The histological evaluation included a cell count of osteogenic cells and a descriptive evaluation of the histological images. The animal trial was accompanied by frequent blood, urine, and X‐ray tests. The results showed adequate degradation of ZnAg3 with an implant area of 93.92% ± 5.85% at week 16 and a sufficient number of osteogenic cells, allowing progressive osteointegration. In comparison, the MAGNEZIX pin degraded significantly faster and, after 16 weeks, diminished to 77.54% ± 13.59% of the original implant area. Furthermore, harmful hydrogen gas pockets were found, which correlated with reduced bone formation, represented by a lower cell count of osteoblasts after 4 weeks. ICP‐OES measurements performed on the animals' blood samples did not reveal any increased metal ion concentrations above the tolerable level. Thus, ZnAg3 pins showed excellent results compared to MAGNEZIX pins, which are in clinical use as bioabsorbable implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlloysAbsorbable ImplantsZincMagnesiumSilverFractures, BoneAnimalsRabbitsMaterials TestingBone Nails

Stichwörter der Autor:innen

biodegradableimplantationosteosynthesisrabbit modelzinc alloyzinc silver alloy

Substanzen

AlloysZincMagnesiumSilver

Autor:innen und Institutionen

  • G.E.R.N. Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Fre…
  • Limedion GmbH, Coatings and Surface Analysis, Mannheim, Germany.
  • Quadralux e.K., Mannheim, Germany.
  • Department of Orthopedic and Trauma Surgery, Medical Center-University of Freiburg, Faculty of Medicine, Freiburg, Germany.

ORCID-Profile: Michael Seidenstuecker

Förderung

  • Bundesministerium für Wirtschaft und Energie

Zitieren

APA

Roesner, M., Baghnavi, A., Riedel, B., Kovacs, A., Benner, M., Barkhoff, R., Schmal, H., Kubosch, E. J., & Seidenstuecker, M. (2025). In Vivo Evaluation of ZnAg3—A New Bioabsorbable Material in Fracture Treatment Compared to Biodegradable Mg Alloys. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 113(9). https://doi.org/10.1002/jbm.b.35647

Vancouver

Roesner M, Baghnavi A, Riedel B, Kovacs A, Benner M, Barkhoff R, et al. In Vivo Evaluation of ZnAg3—A New Bioabsorbable Material in Fracture Treatment Compared to Biodegradable Mg Alloys. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2025;113(9). doi:10.1002/jbm.b.35647

BibTeX
@article{Roesner2025,
  author = {Roesner, Maria and Baghnavi, Anna and Riedel, Bianca and Kovacs, Adalbert and Benner, Moritz and Barkhoff, Roland and Schmal, Hagen and Kubosch, Eva Johanna and Seidenstuecker, Michael},
  title = {In Vivo Evaluation of ZnAg3—A New Bioabsorbable Material in Fracture Treatment Compared to Biodegradable Mg Alloys},
  journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
  year = {2025},
  volume = {113},
  number = {9},
  doi = {10.1002/jbm.b.35647}
}
Kostenlos starten →