EUVIMEDEUVIMED entdecken
Crossref

Cytocompatibility, antibacterial, and corrosion properties of chitosan/polymethacrylates and chitosan/poly(4‐vinylpyridine) smart coatings, electrophoretically deposited on nanosilver‐decorated titania nanotubes

Łukasz Pawłowski iD, Michał Bartmański iD, Anna Ronowska iD, Adrianna Banach-Kopeć iD, Szymon Mania iD, Bartłomiej Michał Cieślik iD, Aleksandra Mielewczyk-Gryń iD, Jakub Karczewski iD, Andrzej Zieliński iD

Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2024

DOI: 10.1002/jbm.b.35332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2024. Verfasst von Łukasz Pawłowski und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdańsk University of Technology, Gdańsk, …. Hauptthemen laut MEDLINE: Chitosan, Metal Nanoparticles, Nanotubes, Polymethacrylic Acids. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 58 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of novel implants subjected to surface modification to achieve high osteointegration properties at simultaneous antimicrobial activity is a highly current problem. This study involved different surface treatments of titanium surface, mainly by electrochemical oxidation to produce a nanotubular oxide layer (TNTs), a subsequent electrochemical reduction of silver nitrate and decoration of a nanotubular surface with silver nanoparticles (AgNPs), and finally electrophoretic deposition (EPD) of a composite of chitosan (CS) and either polymethacrylate‐based copolymer Eudragit E 100 (EE100) or poly(4‐vinylpyridine) (P4VP) coating. The effects of each stage of this multi‐step modification were examined in terms of morphology, roughness, wettability, corrosion resistance, coating‐substrate adhesion, antibacterial properties, and osteoblast cell adhesion and proliferation. The results showed that the titanium surface formed nanotubes (inner diameter of 97 ± 12 nm, length of 342 ± 36 nm) subsequently covered with silver nanoparticles (with a diameter of 88 ± 8 nm). Further, the silver‐decorated nanotubes were tightly coated with biopolymer films. Most of the applied modifications increased both the roughness and the surface contact angle of the samples. The deposition of biopolymer coatings resulted in reduced burst release of silver. The coated samples revealed potent antimicrobial activity against both Gram‐positive and Gram‐negative bacteria. Total elimination (99.9%) of E. coli was recorded for a sample with CS/P4VP coating. Cytotoxicity results using hFOB 1.19, a human osteoblast cell line, showed that after 3 days the tested modifications did not affect the cellular growth according to the titanium control. The proposed innovative multilayer antibacterial coatings can be successful for titanium implants as effective postoperative anti‐inflammation protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChitosanMetal NanoparticlesNanotubesPolymethacrylic AcidsPolyvinylsHumansAnti-Bacterial AgentsTitaniumCorrosionEscherichia coliCoated Materials, BiocompatibleGram-Negative BacteriaGram-Positive BacteriaSilverSurface Properties

Stichwörter der Autor:innen

antibacterial propertiescorrosioncytotoxicitynanosilversmart biopolymerstitanium

Substanzen

Anti-Bacterial Agentspolymethacrylic acidChitosantitanium dioxideTitaniumpoly(4-vinylpyridine)Coated Materials, BiocompatibleSilverPolymethacrylic AcidsPolyvinyls

Autor:innen und Institutionen

  • Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdańsk University of Technology, Gdańsk, Poland.
  • Department of Laboratory Medicine, Medical University of Gdańsk, Gdańsk, Poland.
  • Department of Chemistry, Technology, and Biotechnology of Food, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland.
  • Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland.
  • Institute of Nanotechnology and Materials Engineering, Faculty of Applied Physics and Mathematics, and Advanced Materials Centre, Gdańsk University of Technology, Gdańsk, Poland.

ORCID-Profile: Łukasz Pawłowski, Michał Bartmański, Anna Ronowska, Adrianna Banach-Kopeć, Szymon Mania, Bartłomiej Michał Cieślik, Aleksandra Mielewczyk-Gryń, Jakub Karczewski, Andrzej Zieliński

Zitieren

APA

Pawłowski, Ł., Bartmański, M., Ronowska, A., Banach-Kopeć, A., Mania, S., Cieślik, B. M., Mielewczyk-Gryń, A., Karczewski, J., & Zieliński, A. (2024). Cytocompatibility, antibacterial, and corrosion properties of chitosan/polymethacrylates and chitosan/poly(4‐vinylpyridine) smart coatings, electrophoretically deposited on nanosilver‐decorated titania nanotubes. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.35332

Vancouver

Pawłowski Ł, Bartmański M, Ronowska A, Banach-Kopeć A, Mania S, Cieślik BM, et al. Cytocompatibility, antibacterial, and corrosion properties of chitosan/polymethacrylates and chitosan/poly(4‐vinylpyridine) smart coatings, electrophoretically deposited on nanosilver‐decorated titania nanotubes. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2024. doi:10.1002/jbm.b.35332

BibTeX
@article{Pawowski2024,
  author = {Pawłowski, Łukasz and Bartmański, Michał and Ronowska, Anna and Banach-Kopeć, Adrianna and Mania, Szymon and Cieślik, Bartłomiej Michał and Mielewczyk-Gryń, Aleksandra and Karczewski, Jakub and Zieliński, Andrzej},
  title = {Cytocompatibility, antibacterial, and corrosion properties of chitosan/polymethacrylates and chitosan/poly(4‐vinylpyridine) smart coatings, electrophoretically deposited on nanosilver‐decorated titania nanotubes},
  journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
  year = {2024},
  doi = {10.1002/jbm.b.35332}
}
Kostenlos starten →