Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part A, online erschienen am 01.07.2026. Verfasst von Puttikorn Pukfukdee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, Thailand. Hauptthemen laut MEDLINE: Hyaluronic Acid, Skin Aging, Needles, Cross-Linking Reagents. Die Arbeit nennt 31 Literaturangaben. Gefördert von: the Board of Investment of Thailand.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Delivering a persistent biopolymer matrix to the superficial dermis remains a significant challenge for microneedle systems due to the inherent limitations of conventional dissolving platforms. Here, we present a detachable microneedle design that permits rapid needle separation during administration. To biologically compensate for the relatively short 350 μm needle geometry designed for at‐home safety, this system utilizes a crosslinked hyaluronic acid (cHA) matrix loaded with cosmetic peptides and functional excipients. The primary objective is to reliably deliver this composite biochemical cHA matrix into the skin to a depth of ~300 μm, which corresponds to the dermal–epidermal junction. Segmented mechanical compression analysis revealed that the non‐polymeric payload did not compromise the matrix; rather, it significantly improved the initial axial stiffness from 0.059 ± 0.004 to 0.081 ± 0.005 N/mm per needle. This structural enhancement minimized axial displacement under load, enabling the 350 μm needles to reliably reach an ex vivo penetration depth of 335 ± 22 μm. A 14‐day clinical evaluation ( n = 28) using three‐dimensional topography demonstrated excellent clinical tolerability with no adverse effects and significant reductions in surface roughness ( R a ) and maximum wrinkle height ( R t ) both immediately and at the conclusion of treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hyaluronic AcidSkin AgingNeedlesCross-Linking ReagentsMicroneedle Drug DeliveryHumansAnimalsFemale

Stichwörter der Autor:innen

anti‐wrinkle efficacycrosslinked hyaluronic acid (cHA)dermal–epidermal junction (DEJ)mechanical enhancementmicroneedles

Substanzen

Hyaluronic AcidCross-Linking Reagents

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom, Thailand.
  • Mineed Technology Co. Ltd., Bangkok, Thailand.
  • Department of Materials Science and Engineering, Sustainable Materials Laboratory, Faculty of Engineering and Industrial Technology, Silpakorn University, Nakhon Pathom, Thailand.
  • Department of Medicine, Division of Dermatology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Department of Chemistry, Center of Excellence in Materials and Bio-Interfaces, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.

Förderung

  • the Board of Investment of Thailand

Zitieren

APA

Pukfukdee, P., Ampawa, S., Littirak, W., Suttiruengwong, S., Asawanonda, P., & Wanichwecharungruang, S. (2026). Bioactive‐Loaded Detachable Crosslinked Hyaluronic Acid Microneedles: Structural Validation and Clinical Anti‐Wrinkle Efficacy. Journal of Biomedical Materials Research Part A, 114(7). https://doi.org/10.1002/jbm.a.70113

Vancouver

Pukfukdee P, Ampawa S, Littirak W, Suttiruengwong S, Asawanonda P, Wanichwecharungruang S. Bioactive‐Loaded Detachable Crosslinked Hyaluronic Acid Microneedles: Structural Validation and Clinical Anti‐Wrinkle Efficacy. Journal of Biomedical Materials Research Part A. 2026;114(7). doi:10.1002/jbm.a.70113

BibTeX
@article{Pukfukdee2026,
  author = {Pukfukdee, Puttikorn and Ampawa, Supanan and Littirak, Wirada and Suttiruengwong, Supakij and Asawanonda, Pravit and Wanichwecharungruang, Supason},
  title = {Bioactive‐Loaded Detachable Crosslinked Hyaluronic Acid Microneedles: Structural Validation and Clinical Anti‐Wrinkle Efficacy},
  journal = {Journal of Biomedical Materials Research Part A},
  year = {2026},
  volume = {114},
  number = {7},
  doi = {10.1002/jbm.a.70113}
}
Kostenlos starten →