EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Computed tomography technologies to measure key structural features of polymeric biomedical implants from bench to bedside

Kendell M Pawelec iD, Todd A Schoborg, Erik M Shapiro

Journal of Biomedical Materials Research Part A · 2024

DOI: 10.1002/jbm.a.37735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part A, 2024. Verfasst von Kendell M Pawelec und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Michigan State University, East Lansing, Michigan, USA. Hauptthemen laut MEDLINE: Polymers. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NHLBI NIH HHS, NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implanted polymeric devices, designed to encourage tissue regeneration, require porosity. However, characterizing porosity, which affects many functional device properties, is non‐trivial. Computed tomography (CT) is a quick, versatile, and non‐destructive way to gain 3D structural information, yet various CT technologies, such as benchtop, preclinical and clinical systems, all have different capabilities. As system capabilities determine the structural information that can be obtained, seamless monitoring of key device features through all stages of clinical translation must be engineered intentionally. Therefore, in this study we tested feasibility of obtaining structural information in pre‐clinical systems and high‐resolution micro‐CT (μCT) under physiological conditions. To overcome the low CT contrast of polymers in hydrated environments, radiopaque nanoparticle contrast agent was incorporated into porous devices. The size of resolved features in porous structures is highly dependent on the resolution (voxel size) of the scan. As the voxel size of the CT scan increased (lower resolution) from 5 to 50 μm, the measured pore size was overestimated, and percentage porosity was underestimated by nearly 50%. With the homogeneous introduction of nanoparticles, changes to device structure could be quantified in the hydrated state, including at high‐resolution. Biopolymers had significant structural changes post‐hydration, including a mean increase of 130% in pore wall thickness that could potentially impact biological response. By incorporating imaging capabilities into polymeric devices, CT can be a facile way to monitor devices from initial design stages through to clinical translation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolymersPorosityProstheses and ImplantsTomography, X-Ray ComputedX-Ray MicrotomographyAnimalsHumansBiocompatible MaterialsNanoparticlesContrast Media

Stichwörter der Autor:innen

biomedical devicescomputed tomographymedical imagingporosity

Substanzen

PolymersBiocompatible MaterialsContrast Media

Autor:innen und Institutionen

  • Department of Radiology, Michigan State University, East Lansing, Michigan, USA.
  • Institute for Quantitative Health Sciences and Engineering, Michigan State University, East Lansing, Michigan, USA.
  • Department of Molecular Biology, University of Wyoming, Laramie, Wyoming, USA.
  • Department of Physiology, Michigan State University, East Lansing, Michigan, USA.
  • Department of Chemical Engineering and Material Science, Michigan State University, East Lansing, Michigan, USA.
  • Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan, USA.

ORCID-Profile: Kendell M Pawelec

Förderung

  • NHLBI NIH HHS
  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Pawelec, K. M., Schoborg, T. A., & Shapiro, E. M. (2024). Computed tomography technologies to measure key structural features of polymeric biomedical implants from bench to bedside. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.37735

Vancouver

Pawelec KM, Schoborg TA, Shapiro EM. Computed tomography technologies to measure key structural features of polymeric biomedical implants from bench to bedside. Journal of Biomedical Materials Research Part A. 2024. doi:10.1002/jbm.a.37735

BibTeX
@article{Pawelec2024,
  author = {Pawelec, Kendell M and Schoborg, Todd A and Shapiro, Erik M},
  title = {Computed tomography technologies to measure key structural features of polymeric biomedical implants from bench to bedside},
  journal = {Journal of Biomedical Materials Research Part A},
  year = {2024},
  doi = {10.1002/jbm.a.37735}
}
Kostenlos starten →