Effect of static tensile stress on enzymatic degradation of poly(glycerol sebacate)
Journal of Biomedical Materials Research Part A · 2023-10 · 111 (10) · 1513-1524
DOI: 10.1002/jbm.a.37550 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part A, online erschienen am 18.04.2023. Verfasst von Zebin Wu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Centre for Biomedical Engineering, School of…. Hauptthemen laut MEDLINE: Polymers, Decanoates. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Beijing Municipal Natural Science Foundation, Higher Education Discipline Innovation Project, National Natural Science Foundation of China.
Abstract (Originalsprache)
Poly(glycerol sebacate) (PGS) is an excellent scaffold material in tissue engineering due to good biocompatibility and tunable mechanical properties. The degradation properties of PGS have been primarily explored in static phosphate buffer solution or enzyme solution. It is vital to understand how the tensile stress affect the degradation rate. In this study, PGS was synthetized by melt polycondensation and its properties were characterized. Then an in vitro degradation device which could provide different constant tensile stresses was carefully designed and established, and the enzymatic degradation of PGS was tested under 0–150 kPa at 37°C. It was found that holes of PGS surface arranged almost parallel to each other and perpendicular to the direction of tensile stresses at 100 kPa and 150 kPa after 2–4 days degradation. After 8 days degradation, the ultimate tensile strength (UTS) of PGS at 150 kPa was 0.28 MPa and the elastic modulus was 1.11 MPa, while the UTS of PGS was 0.44 MPa and the elastic modulus was 1.63 MPa before degradation, both of them have significant differences. Hence, the tensile stress and degradation time were proportional to the appear time and size of holes, leading to the decrease of mass loss, UTS and elastic modulus. The relationship between stress and PGS degradation rates was quantitatively described through our degradation experiments, providing guidance for suitable PGS applications in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Centre for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beiji…
- School of Engineering Medicine, Beihang University, Beijing, China.
ORCID-Profile: Lizhen Wang
Förderung
- Beijing Municipal Natural Science Foundation
- Higher Education Discipline Innovation Project
- National Natural Science Foundation of China
Zitieren
APA
Wu, Z., Wang, L., & Fan, Y. (2023). Effect of static tensile stress on enzymatic degradation of poly(glycerol sebacate). Journal of Biomedical Materials Research Part A, 111(10), 1513-1524. https://doi.org/10.1002/jbm.a.37550
Vancouver
Wu Z, Wang L, Fan Y. Effect of static tensile stress on enzymatic degradation of poly(glycerol sebacate). Journal of Biomedical Materials Research Part A. 2023;111(10):1513-1524. doi:10.1002/jbm.a.37550
BibTeX
@article{Wu2023,
author = {Wu, Zebin and Wang, Lizhen and Fan, Yubo},
title = {Effect of static tensile stress on enzymatic degradation of poly(glycerol sebacate)},
journal = {Journal of Biomedical Materials Research Part A},
year = {2023},
volume = {111},
number = {10},
pages = {1513--1524},
doi = {10.1002/jbm.a.37550}
}