Fachartikel in der Zeitschrift Journal of Biomedical Materials Research, online erschienen am 05.09.2002. Verfasst von F Rupp und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, Medical Materials and Technology, University of Tuebingen, Osianderstrasse 2-8, D-72076 Tuebingen, Germany. frank…. Die Arbeit wurde bisher 51-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: German Research Society (Deutsche Forschungsgemeinschaft, DFG).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As a result of inflammatory processes, plaque formation on dental titanium implants often leads to clinically pathogenic situations. This special biofilm formation on (bio)materials in contact with saliva is initiated by ionic and protein interactions. In this interfacial process, albumin becomes a main constituent of dental pellicle. Interfacial reactions change the surface characteristics. They determine the following steps of macromolecular adsorption and bacterial adhesion. This work focuses on the dynamic contact angle analysis (DCA), which is a tool for online measurements of dynamic changes of wettability without disturbing the interface during detection. Repeatability of the DCA method has been assessed according to the Bland and Altman method. The kinetics and equilibrium data of shifts in the wetting tension hysteresis indicate ionic influences at the titanium/bovine serum albumin (BSA) interface: the Ca‐mediated increase of the BSA adsorption on titanium and the adsorption maximum at the isoelectric point (IEP) of BSA. Ti was surface modified by Teflon® AF polymeric coatings. The result of the assessment gives reason to consider Teflon® AF as a reference material for DCA repeatability studies. This surface modification caused drastic changes in the dynamic interfacial reactions. Shifts in the wetting tensions during DCA adsorption‐desorption experiments clearly demonstrated the partially irreversible adsorption of BSA on Teflon® AF. In contrast, reversible adsorption behavior was detected on pure Ti surfaces. These findings strengthen the hypothesis that the analysis of dynamic changes in wetting tension and wetting tension hysteresis is a sensitive analytical method for the detection of dynamic interfacial changes at biomaterial/biosystem interfaces during the initial steps of biofilm formation. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 567–578, 2002

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdsorptionAnimalsCattleCoated Materials, BiocompatibleDental PellicleHydrogen-Ion ConcentrationMaterials TestingPolytetrafluoroethyleneProstheses and ImplantsRegression AnalysisReproducibility of ResultsSerum Albumin, BovineSurface PropertiesTitaniumWettability

Substanzen

Coated Materials, BiocompatibleSerum Albumin, BovinePolytetrafluoroethyleneTitanium

Autor:innen und Institutionen

  • Department of Prosthetic Dentistry, Medical Materials and Technology, University of Tuebingen, Osianderstrasse 2-8, D-72076 Tuebingen, Germany. frank.rupp@med.uni-tuebingen.de

Förderung

  • German Research Society (Deutsche Forschungsgemeinschaft, DFG)

Zitieren

APA

Rupp, F., Axmann, D., Ziegler, C., & Geis-Gerstorfer, J. (2002). Adsorption/desorption phenomena on pure and Teflon® AF‐coated titania surfaces studied by dynamic contact angle analysis. Journal of Biomedical Materials Research, 62(4), 567-578. https://doi.org/10.1002/jbm.10198

Vancouver

Rupp F, Axmann D, Ziegler C, Geis-Gerstorfer J. Adsorption/desorption phenomena on pure and Teflon® AF‐coated titania surfaces studied by dynamic contact angle analysis. Journal of Biomedical Materials Research. 2002;62(4):567-578. doi:10.1002/jbm.10198

BibTeX
@article{Rupp2002,
  author = {Rupp, F and Axmann, D and Ziegler, C and Geis-Gerstorfer, J},
  title = {Adsorption/desorption phenomena on pure and Teflon® AF‐coated titania surfaces studied by dynamic contact angle analysis},
  journal = {Journal of Biomedical Materials Research},
  year = {2002},
  volume = {62},
  number = {4},
  pages = {567--578},
  doi = {10.1002/jbm.10198}
}
Kostenlos starten →