EUVIMEDEUVIMED entdecken
Crossref

Improvement in zirconia osseointegration by means of a biological glass coating: An in vitro and in vivo investigation

N Nicoli Aldini, M Fini, G Giavaresi, P Torricelli, L Martini, R Giardino, A Ravaglioli, A Krajewski, M Mazzocchi, B Dubini, M G Ponzi-Bossi, F Rustichelli und 1 weitere

Journal of Biomedical Materials Research · 2002-08 · 61 (2) · 282-289

DOI: 10.1002/jbm.10162 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research, online erschienen am 26.04.2002. Verfasst von N Nicoli Aldini und 12 weiteren Autor:innen. Beteiligte Einrichtung: Experimental Surgery Department, Research Institute Codivilla Putti-Rizzoli Orthopaedic Institute via di Barbiano 1/10, 40136, Bologna, Italy. nicolo…. Hauptthemen laut MEDLINE: Materials Testing, Osseointegration. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biocompatibility and osseointegration of zirconia (ZrO 2 ), either coated with RKKP bioglaze® or uncoated, were evaluated in vitro and in vivo . The in vitro test was performed in human osteoblasts, whereas maximal sensitization was performed in 23 Dunkin Hurtley guinea pigs. RKKP bioglaze‐coated and uncoated (controls) ZrO 2 cylinders were implanted in the distal femoral epiphyses of 14 Sprague‐Dawley rats under general anesthesia, and animals were sacrificed at 30 and 60 days. Lactate dehydrogenase, alkaline phosphatase, and Thiazolyl Blue (MTT) were tested in vitro . A graded score was used for evaluating the results of the sensitization test. Histomorphometry and microhardness testing were performed to quantify the osseointegration rate, as well as bone quality around the implants. Neither in vitro cytotoxicity nor sensitization were observed. Histomorphometry demonstrated that at 30 days, the affinity index was significantly higher in coated implants than in uncoated ones ( p < 0.05); at 60 days, the behavior of coated implants was better than that of uncoated ones, but differences were not significant. Significant increases in bone microhardness were found at 1000 μm from the interface area for both uncoated ( p < 0.0005) and RKKP bioglaze®‐coated ( p < 0.0005) ZrO 2 , and also within 200 μm from the interface ( p = 0.014) but only for coated ZrO 2. These results suggest that RKKP bioglaze®‐coated ZrO 2 permits biocompatible devices with improved osseointegration properties to be manufactured. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 282–289, 2002

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Materials TestingOsseointegrationAnimalsBone SubstitutesCell DeathCeramicsCoated Materials, BiocompatibleFemaleGuinea PigsHumansImmunizationImplants, ExperimentalMechanicsOsteoblastsRatsSurvival RateZirconium

Substanzen

BioglassBone SubstitutesCoated Materials, BiocompatibleZirconiumzirconium oxide

Autor:innen und Institutionen

  • Experimental Surgery Department, Research Institute Codivilla Putti-Rizzoli Orthopaedic Institute via di Barbiano 1/10, 40136, Bologna, Italy. nicolo.nicolialdini@ior.it

Zitieren

APA

Aldini, N. N., Fini, M., Giavaresi, G., Torricelli, P., Martini, L., Giardino, R., Ravaglioli, A., Krajewski, A., Mazzocchi, M., Dubini, B., Ponzi-Bossi, M. G., Rustichelli, F., & Stanic, V. (2002). Improvement in zirconia osseointegration by means of a biological glass coating: An in vitro and in vivo investigation. Journal of Biomedical Materials Research, 61(2), 282-289. https://doi.org/10.1002/jbm.10162

Vancouver

Aldini NN, Fini M, Giavaresi G, Torricelli P, Martini L, Giardino R, et al. Improvement in zirconia osseointegration by means of a biological glass coating: An in vitro and in vivo investigation. Journal of Biomedical Materials Research. 2002;61(2):282-289. doi:10.1002/jbm.10162

BibTeX
@article{Aldini2002,
  author = {Aldini, N Nicoli and Fini, M and Giavaresi, G and Torricelli, P and Martini, L and Giardino, R and Ravaglioli, A and Krajewski, A and Mazzocchi, M and Dubini, B and Ponzi-Bossi, M G and Rustichelli, F and Stanic, V},
  title = {Improvement in zirconia osseointegration by means of a biological glass coating: An in vitro and in vivo investigation},
  journal = {Journal of Biomedical Materials Research},
  year = {2002},
  volume = {61},
  number = {2},
  pages = {282--289},
  doi = {10.1002/jbm.10162}
}
Kostenlos starten →