EUVIMEDEUVIMED entdecken
Crossref

Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening

A M Arunnagiri iD, M Sasikala, N Ramadass, S Mullai Venthan

Journal of Biophotonics · 2025

DOI: 10.1002/jbio.70024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2025. Verfasst von A M Arunnagiri und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Communication Engineering, College of Engineering, Guindy, Anna University, Chennai, India. Hauptthemen laut MEDLINE: Microscopy, Anemia, High-Throughput Screening Assays. Die Arbeit nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The conventional method of screening for anemia requires pathologists to manually examine slides via microscope, a tedious process during health emergencies. This study presents an automated high‐throughput optical digital microscope system capable of sequentially scanning and analyzing 10 blood smear slides per batch in under 15 min using a Laplacian‐based autofocusing algorithm at 40x magnification. The acquired images are segmented via the YOLOv5 algorithm, and morphological features of red blood cells (RBCs) are classified using a multilayer perceptron (MLP) model. The system achieved 90.6% accuracy, 95% precision, 91% sensitivity, and 94% specificity in classifying anemia subtypes (macrocytic, microcytic, normocytic) and healthy samples. The trained model is integrated into an Android application for real‐time geographic mapping of anemic clusters, enabling healthcare workers to prioritize interventions efficiently. This high‐throughput approach eliminates the need for immersion oil and manual slide handling, demonstrating significant potential for rapid, scalable anemia screening in resource‐limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroscopyAnemiaHigh-Throughput Screening AssaysHumansErythrocytesImage Processing, Computer-AssistedAlgorithms

Stichwörter der Autor:innen

3D printed optical assembly holderMLP classifierRBC analysisYOLOblood smear imageshigh‐throughput optical assemblysmartphone application

Autor:innen und Institutionen

  • Department of Electronics and Communication Engineering, College of Engineering, Guindy, Anna University, Chennai, India.

ORCID-Profile: A M Arunnagiri

Zitieren

APA

Arunnagiri, A. M., Sasikala, M., Ramadass, N., & Mullai Venthan, S. (2025). Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening. Journal of Biophotonics. https://doi.org/10.1002/jbio.70024

Vancouver

Arunnagiri AM, Sasikala M, Ramadass N, Mullai Venthan S. Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening. Journal of Biophotonics. 2025. doi:10.1002/jbio.70024

BibTeX
@article{Arunnagiri2025,
  author = {Arunnagiri, A M and Sasikala, M and Ramadass, N and Mullai Venthan, S},
  title = {Development of a High‐Throughput Microscope for the Analysis of Peripheral Blood Smears for Anemia Screening},
  journal = {Journal of Biophotonics},
  year = {2025},
  doi = {10.1002/jbio.70024}
}
Kostenlos starten →