EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved Sensitivity in Large Field of View Multispectral Laser‐Scanning Photoacoustic Microscopy for Measuring Oxygen Saturation In Vivo

Mohsin Zafar, Amir Khansari, Rayyan Manwar iD, Kamran Avanaki iD

Journal of Biophotonics · 2026

DOI: 10.1002/jbio.202500378 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2026. Verfasst von Mohsin Zafar und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Oxygen, Oxygen Saturation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multispectral photoacoustic microscopy (PAM) using stimulated Raman scattering (SRS) has been employed to measure oxygen saturation (sO 2 ) in biological tissue. However, laser‐scanning photoacoustic microscopy (LS‐PAM) inherently suffers from low detection sensitivity due to the use of a flat transducer and non‐coaxial alignment of the transducer with the optical scan. Although wide‐field‐of‐view LS‐PAM has been implemented, it typically results in coarser lateral resolution and hence lower sensitivity than existing LS‐PAM systems. Here, we present a wide‐field multispectral LS‐PAM system for measuring sO 2 in biological tissue. Instead of relying on two discrete wavelengths, our method employs two wavelength groups—a isosbestic group (532 nm and 545 nm) and a deoxyhemoglobin‐dominant group (545 nm and 558 nm). We demonstrate that using these groups improves the signal‐to‐noise ratio (SNR) of the detected signals, leading to more accurate sO 2 measurements. The performance of this system is validated through both phantom and in vivo studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Photoacoustic TechniquesOxygenOxygen SaturationAnimalsSignal-To-Noise RatioPhantoms, ImagingMicroscopy, ConfocalMice

Stichwörter der Autor:innen

in vivomicroscopyoxygen saturationphotoacousticspectroscopy

Substanzen

Oxygen

Autor:innen und Institutionen

  • The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Department of Dermatology and Pediatrics, University of Illinois at Chicago, Chicago, Illinois, USA.

ORCID-Profile: Rayyan Manwar, Kamran Avanaki

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Zafar, M., Khansari, A., Manwar, R., & Avanaki, K. (2026). Improved Sensitivity in Large Field of View Multispectral Laser‐Scanning Photoacoustic Microscopy for Measuring Oxygen Saturation In Vivo. Journal of Biophotonics. https://doi.org/10.1002/jbio.202500378

Vancouver

Zafar M, Khansari A, Manwar R, Avanaki K. Improved Sensitivity in Large Field of View Multispectral Laser‐Scanning Photoacoustic Microscopy for Measuring Oxygen Saturation In Vivo. Journal of Biophotonics. 2026. doi:10.1002/jbio.202500378

BibTeX
@article{Zafar2026,
  author = {Zafar, Mohsin and Khansari, Amir and Manwar, Rayyan and Avanaki, Kamran},
  title = {Improved Sensitivity in Large Field of View Multispectral Laser‐Scanning Photoacoustic Microscopy for Measuring Oxygen Saturation In Vivo},
  journal = {Journal of Biophotonics},
  year = {2026},
  doi = {10.1002/jbio.202500378}
}
Kostenlos starten →