EUVIMEDEUVIMED entdecken
Crossref

Coherent‐Excitation PACT With Frequency‐Compensated Reconstruction for High‐Contrast Deep‐Tissue Imaging

Ruijie Hou, Jun Ye, Yang Zhang, Feng Hua, Bin Xu, Xuefeng Liu, Muhammad Qasim Mehmood iD, Jichuan Xiong iD

Journal of Biophotonics · 2025

DOI: 10.1002/jbio.202500175 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2025. Verfasst von Ruijie Hou und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Photoacoustic Techniques, Tomography, X-Ray Computed. Die Arbeit nennt 13 Literaturangaben. Gefördert von: Ministry of Science and Technology international collaborative project, National Major Scientific Instruments and Equipment Development Project, Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoacoustic computed tomography (PACT) synergizes optical absorption contrast with ultrasonic resolution for noninvasive biomedical imaging yet faces limitations in signal‐to‐noise ratio (SNR), resolution, and contrast. This study introduces a coherent‐excitation PACT system integrating interferometric optical excitation and Frequency‐Compensated Filtered Back Projection (FC‐FBP) reconstruction. The proposed method utilizes phase‐locked dual‐pulse interferometric excitation to amplify photoacoustic emissions; for the isolated chicken heart, the resolution is improved by 7.9% compared to the single‐pulse protocol. The FC‐FBP algorithm compensates for frequency‐dependent acoustic attenuation via depth‐adaptive Gaussian filtering, enhancing the projected signal in the target area while suppressing speckle artifacts. Through experimental validation, we confirm that the coherent‐excitation scheme enables simultaneous optimization of optical fluence distribution and acoustic coherence; hence, it can be used to resolve previously indistinguishable hemoglobin oxygenation gradients in murine tumor models. This advancement establishes a high‐sensitivity PACT framework, showing potential for real‐time intraoperative imaging and dynamic metabolic monitoring in clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedPhotoacoustic TechniquesTomography, X-Ray ComputedAnimalsMiceSignal-To-Noise RatioChickensHeart

Stichwörter der Autor:innen

coherent‐excitationfrequency‐compensated filtered back projectionnoninvasive biomedical imagingphotoacoustic computed tomography

Autor:innen und Institutionen

  • School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, China.
  • School of Artificial Intelligence, Luoyang Institute of Science and Technology, Luoyang, China.
  • MicroNano Lab, Information Technology University of the Punjab (ITU), Lahore, Pakistan.

ORCID-Profile: Muhammad Qasim Mehmood, Jichuan Xiong

Förderung

  • Ministry of Science and Technology international collaborative project
  • National Major Scientific Instruments and Equipment Development Project, Natural Science Foundation of China

Zitieren

APA

Hou, R., Ye, J., Zhang, Y., Hua, F., Xu, B., Liu, X., Mehmood, M. Q., & Xiong, J. (2025). Coherent‐Excitation PACT With Frequency‐Compensated Reconstruction for High‐Contrast Deep‐Tissue Imaging. Journal of Biophotonics. https://doi.org/10.1002/jbio.202500175

Vancouver

Hou R, Ye J, Zhang Y, Hua F, Xu B, Liu X, et al. Coherent‐Excitation PACT With Frequency‐Compensated Reconstruction for High‐Contrast Deep‐Tissue Imaging. Journal of Biophotonics. 2025. doi:10.1002/jbio.202500175

BibTeX
@article{Hou2025,
  author = {Hou, Ruijie and Ye, Jun and Zhang, Yang and Hua, Feng and Xu, Bin and Liu, Xuefeng and Mehmood, Muhammad Qasim and Xiong, Jichuan},
  title = {Coherent‐Excitation PACT With Frequency‐Compensated Reconstruction for High‐Contrast Deep‐Tissue Imaging},
  journal = {Journal of Biophotonics},
  year = {2025},
  doi = {10.1002/jbio.202500175}
}
Kostenlos starten →