Neuronal Imaging at 8‐Bit Depth to Combine High Spatial and High Temporal Resolution With Acquisition Rates Up To 40 kHz
Journal of Biophotonics · 2025
DOI: 10.1002/jbio.202400513 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biophotonics, 2025. Verfasst von Fatima Abbas und 3 weiteren Autor:innen. Beteiligte Einrichtung: Univ. Grenoble Alpes, CNRS, LIPhy, Grenoble, France. Hauptthemen laut MEDLINE: Neurons, Optical Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A challenge in neuroimaging is acquiring frame sequences at high temporal resolution from the largest possible number of pixels. Measuring 1%–10% fluorescence changes normally requires 12‐bit or higher bit depth, constraining the frame size allowing imaging in the kHz range. We resolved Ca 2+ or membrane potential signals from cell populations or single neurons in brain slices by acquiring fluorescence at 8‐bit depth and by binning pixels offline, achieving unprecedented frame sizes at kHz rates. In hippocampal slices stained with the Ca 2+ indicator Fluo‐4 AM, we resolved transients at 2 kHz from large frames. Along the apical dendrite of a layer‐5 pyramidal neuron, we measured Ca 2+ signals associated with a back‐propagating action potential at 10 kHz. Finally, in the axon initial segment of the same cell type, we recorded an action potential at 40 kHz by voltage‐sensitive dye imaging. This approach unlocks the potential for a range of imaging measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Univ. Grenoble Alpes, CNRS, LIPhy, Grenoble, France.
- Laboratories of Excellence, Ion Channel Science and Therapeutics, Valbonne, France.
- Institute of Health Sciences/Physiology, Erciyes University, Kayseri, Turkey.
- Department of Physiology, Faculty of Medicine, Kirşehir Ahi Evran University, Kirşehir, Turkey.
- Institut National de la Santé et Recherche Médicale, Paris, France.
ORCID-Profile: Ömer Yusuf İpek, Marco Canepari
Zitieren
APA
Abbas, F., İpek, Ö. Y., Moreau, P., & Canepari, M. (2025). Neuronal Imaging at 8‐Bit Depth to Combine High Spatial and High Temporal Resolution With Acquisition Rates Up To 40 kHz. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400513
Vancouver
Abbas F, İpek ÖY, Moreau P, Canepari M. Neuronal Imaging at 8‐Bit Depth to Combine High Spatial and High Temporal Resolution With Acquisition Rates Up To 40 kHz. Journal of Biophotonics. 2025. doi:10.1002/jbio.202400513
BibTeX
@article{Abbas2025,
author = {Abbas, Fatima and İpek, Ömer Yusuf and Moreau, Philippe and Canepari, Marco},
title = {Neuronal Imaging at 8‐Bit Depth to Combine High Spatial and High Temporal Resolution With Acquisition Rates Up To 40 kHz},
journal = {Journal of Biophotonics},
year = {2025},
doi = {10.1002/jbio.202400513}
}
EUVIMED