Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Zhuanxia He und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China. Hauptthemen laut MEDLINE: Indoles. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Tianjin Municipal Education Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

IR780 iodide is a commercially available targeted near‐infrared contrast agent for in vivo imaging and cancer photodynamic or photothermal therapy, whereas the accumulation, dynamics, and retention of IR780 in biological tissue, especially in tumor is still under‐explored. Diffuse fluorescence tomography (DFT) can be used for localization and quantification of the three‐dimensional distribution of NIR fluorophores. Herein, a homemade DFT imaging system combined with tumor‐targeted IR780 was utilized for cancer imaging and pharmacokinetic evaluation. The aim of this study is to comprehensively assess the biochemical and pharmacokinetic characteristics of IR780 with the aid of DFT imaging. The optimal IR780 concentration (20 μg/mL) was achieved first. Subsequently, the good biocompatibility and cellar uptake of IR780 was demonstrated through the mouse acute toxic test and cell assay. In vivo, DFT imaging effectively identified various subcutaneous tumors and revealed the long‐term retention of IR780 in tumors and rapid metabolism in the liver. Ex vivo imaging indicated IR780 was mainly concentrated in tumor and lung with significantly different from the distribution in other organs. DFT imaging allowed sensitive tumor detection and pharmacokinetic rates analysis. Simultaneously, the kinetics of IR780 in tumors and liver provided more valuable information for application and development of IR780.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IndolesAnimalsMiceCell Line, TumorHumansNeoplasmsTomographyTissue DistributionOptical ImagingTomography, Optical

Stichwörter der Autor:innen

IR780diffuse fluorescence tomographypharmacokinetic parameterstumor detection

Substanzen

2-(2-(2-chloro-3-((1,3-dihydro-3,3-dimethyl-1-propyl-2H-indol-2-ylidene)ethylidene)-1-cyclohexen-1-yl)ethenyl)-3,3-dime…Indoles

Autor:innen und Institutionen

  • College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China.
  • School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, China.
  • School of Medical Imaging, Tianjin Medical University, Tianjin, China.

ORCID-Profile: Zhuanxia He, Lingxiu Xing

Förderung

  • National Natural Science Foundation of China
  • Tianjin Municipal Education Commission

Zitieren

APA

He, Z., Zhang, L., Xing, L., Sun, W., Gao, X., Zhang, Y., & Gao, F. (2024). IR780 ‐based diffuse fluorescence tomography for cancer detection. Journal of Biophotonics. https://doi.org/10.1002/jbio.202300493

Vancouver

He Z, Zhang L, Xing L, Sun W, Gao X, Zhang Y, et al. IR780 ‐based diffuse fluorescence tomography for cancer detection. Journal of Biophotonics. 2024. doi:10.1002/jbio.202300493

BibTeX
@article{He2024,
  author = {He, Zhuanxia and Zhang, Limin and Xing, Lingxiu and Sun, Wenjing and Gao, Xiujun and Zhang, Yanqi and Gao, Feng},
  title = {IR780 ‐based diffuse fluorescence tomography for cancer detection},
  journal = {Journal of Biophotonics},
  year = {2024},
  doi = {10.1002/jbio.202300493}
}
Kostenlos starten →