EUVIMEDEUVIMED entdecken
Crossref

Multiple protein‐patterned surface plasmon resonance biochip for the detection of human immunoglobulin‐G

Ritayan Kashyap, Pearleshwari Rani Boro, Rafika Yasmin, Jugabrat Nath, Durlav Sonowal, Robin Doley, Biplob Mondal iD

Journal of Biophotonics · 2023

DOI: 10.1002/jbio.202200263 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2023. Verfasst von Ritayan Kashyap und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Serum Albumin, Bovine. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 89 Literaturangaben. Gefördert von: Science and Engineering Research Board.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A portable surface plasmon resonance (SPR) measurement prototype integrated with a multiple protein‐patterned SPR biochip is introduced for label‐free and selective detection of human immunoglobulin‐G (H‐IgG). The polyclonal anti‐H‐IgG antibodies derived from goat, rabbit, and mouse were immobilized through polydimethylsiloxane (PDMS) microchannels to fabricate the patterned SPR biochip. The PDMS surface was functionalized using 3‐aminopropyltrimethoxysilane and bonded to carbodiimide‐activated gold substrates to construct irreversibly bonded hydrophilic microfluidic chip at room temperature. For SPR measurement, a custom‐made system is developed with a high angular scanning accuracy of 0.005° and a wide scanning range of 30°–80° that avoids the conventional requirement of expensive goniometric stages and detector arrays. The SPR biochip immobilized with 750 μg/mL goat anti‐H‐IgG demonstrated detection of H‐IgG with a detection limits of 15 μg/mL, and linear response through a wide concentration range (15–225 μg/mL) of high coefficient of determination ( R 2 = 0.99661). The selectivity of the sensor was investigated by exposing them to two different non‐specific targets (bovine serum albumin and polyvalent antivenom). The results indicate negligible sensor response towards nonspecific targets (0.25° for 30 μg/mL bovine serum albumin (BSA) and 0.25° for 30 μg/mL polyvalent antivenom) in comparison to H‐IgG (1.5° for 30 μg/mL).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surface Plasmon ResonanceSerum Albumin, BovineHumansAnimalsMiceRabbitsAntiveninsImmunoglobulin GGoats

Stichwörter der Autor:innen

Kretschmannhuman immunoglobulin-Gmicrofluidicspolydimethylsiloxanesurface plasmon resonance

Substanzen

Serum Albumin, BovineAntiveninsImmunoglobulin G

Autor:innen und Institutionen

  • Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India.
  • Department of Molecular Biology and Biotechnology, Tezpur University, Tezpur, Assam, India.

ORCID-Profile: Biplob Mondal

Förderung

  • Science and Engineering Research Board

Zitieren

APA

Kashyap, R., Boro, P. R., Yasmin, R., Nath, J., Sonowal, D., Doley, R., & Mondal, B. (2023). Multiple protein‐patterned surface plasmon resonance biochip for the detection of human immunoglobulin‐G. Journal of Biophotonics. https://doi.org/10.1002/jbio.202200263

Vancouver

Kashyap R, Boro PR, Yasmin R, Nath J, Sonowal D, Doley R, et al. Multiple protein‐patterned surface plasmon resonance biochip for the detection of human immunoglobulin‐G. Journal of Biophotonics. 2023. doi:10.1002/jbio.202200263

BibTeX
@article{Kashyap2023,
  author = {Kashyap, Ritayan and Boro, Pearleshwari Rani and Yasmin, Rafika and Nath, Jugabrat and Sonowal, Durlav and Doley, Robin and Mondal, Biplob},
  title = {Multiple protein‐patterned surface plasmon resonance biochip for the detection of human immunoglobulin‐G},
  journal = {Journal of Biophotonics},
  year = {2023},
  doi = {10.1002/jbio.202200263}
}
Kostenlos starten →