EUVIMEDEUVIMED entdecken
Crossref

Miniaturized Droplet‐Based Adaptation of the Ames Test for High‐Throughput Mutagenicity Assessment

Jialan Cao, Bayan Nasr, J Michael Köhler, Sebastian Buchinger

Journal of Applied Toxicology · 2026

DOI: 10.1002/jat.70066 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Toxicology, 2026. Verfasst von Jialan Cao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Micro- und Nanotechnologies/Institute for Chemistry and Bioengineering, Technische Universität Ilmenau, Ilmenau, Germany. Hauptthemen laut MEDLINE: Salmonella typhimurium, Mutagens, High-Throughput Screening Assays, Microfluidic Analytical Techniques. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Thuringia Habilitation Fellowship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work presents the first demonstration of a tube‐based droplet microfluidic implementation of the Ames test, bridging single‐droplet resolution with regulatory genotoxicity testing. The Ames test is a cornerstone assay for detecting mutagenicity, but conventional plate‐ and well‐based formats suffer from high reagent consumption, low throughput, and limited automation. We report a droplet‐based microfluidic Ames test assay using Salmonella typhimurium TA98, combining nanoliter compartmentalization with multiparameter optical detection. Cell density screening identified an optimal inoculum range of 10 6 –10 7 cells/mL that maximized sensitivity while limiting spontaneous revertants. Dose–response analysis with the reference mutagen 4‐nitro‐o‐phenylenediamine (4‐NOPD) revealed clear increases in the fraction of droplets with growth of revertants, followed by a cytotoxic suppression at ≥ 8 μg/mL. A threshold‐based evaluation enabled robust quantification of stochastic mutation events at single‐droplet resolution. Compared with the classical fluctuation assay, the microfluidic format reduced reagent consumption by > 90%, generated statistically powerful datasets within 48 h, and eliminated subjective scoring. This study establishes segmented‐flow microfluidics as a scalable, sensitive, and resource‐efficient platform for mutagenicity testing, with applications in regulatory toxicology, environmental monitoring, and high‐throughput chemical screening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Salmonella typhimuriumMutagensHigh-Throughput Screening AssaysMicrofluidic Analytical TechniquesMutagenicity TestsMiniaturizationDose-Response Relationship, DrugMicrofluidics

Stichwörter der Autor:innen

AMESSalmonella typhimurium TA98microfluidicsmutagenicity

Substanzen

Mutagens

Autor:innen und Institutionen

  • Institute for Micro- und Nanotechnologies/Institute for Chemistry and Bioengineering, Technische Universität Ilmenau, Ilmenau, Germany.
  • Federal Institute of Hydrology (BfG), Department G - Qualitative Hydrology, Koblenz, Germany.

Förderung

  • Thuringia Habilitation Fellowship

Zitieren

APA

Cao, J., Nasr, B., Köhler, J. M., & Buchinger, S. (2026). Miniaturized Droplet‐Based Adaptation of the Ames Test for High‐Throughput Mutagenicity Assessment. Journal of Applied Toxicology. https://doi.org/10.1002/jat.70066

Vancouver

Cao J, Nasr B, Köhler JM, Buchinger S. Miniaturized Droplet‐Based Adaptation of the Ames Test for High‐Throughput Mutagenicity Assessment. Journal of Applied Toxicology. 2026. doi:10.1002/jat.70066

BibTeX
@article{Cao2026,
  author = {Cao, Jialan and Nasr, Bayan and Köhler, J Michael and Buchinger, Sebastian},
  title = {Miniaturized Droplet‐Based Adaptation of the Ames Test for High‐Throughput Mutagenicity Assessment},
  journal = {Journal of Applied Toxicology},
  year = {2026},
  doi = {10.1002/jat.70066}
}
Kostenlos starten →