Fachartikel in der Zeitschrift Journal of Applied Toxicology, 2024. Verfasst von Oskari J Uski und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden. Hauptthemen laut MEDLINE: Particulate Matter, Vehicle Emissions. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Swedish Heart Lung Foundation, Västerbotten County Council Spearhead Research Grant, Swedish Research Council for health working life and welfare (FORTE).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In urban areas, inhalation of fine particles from combustion sources such as diesel engines causes adverse health effects. For toxicity testing, a substantial amount of particulate matter (PM) is needed. Conventional sampling involves collection of PM onto substrates by filtration or inertial impaction. A major drawback to those methodologies is that the extraction process can modify the collected particles and alter their chemical composition. Moreover, prior to toxicity testing, PM samples need to be resuspended, which can alter the PM sample even further. Lastly, the choice of the resuspension medium may also impact the detected toxicological responses. In this study, we compared the toxicity profile of PM obtained from two alternative sampling systems, using in vitro toxicity assays. One system makes use of condensational growth before collection in water in an impinger – BioSampler (CG‐BioSampler), and the other, a Dekati® Gravimetric Impactor (DGI), is based on inertial impaction. In addition, various methods for resuspension of DGI collected PM were compared. Tested endpoints included cytotoxicity, formation of cellular reactive oxygen species, and genotoxicity. The alternative collection and suspension methods affected different toxicological endpoints. The water/dimethyl sulfoxide mixture and cell culture medium resuspended particles, along with the CG‐BioSampler sample, produced the strongest responses. The water resuspended sample from the DGI appeared least toxic. CG‐BioSampler collected PM caused a clear increased response in apoptotic cell death. We conclude that the CG‐BioSampler PM sampler is a promising alternative to inertial impaction sampling.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particulate MatterVehicle EmissionsHumansA549 CellsParticle SizeAir PollutantsReactive Oxygen SpeciesCell SurvivalToxicity TestsEnvironmental MonitoringSuspensions

Stichwörter der Autor:innen

apoptosisdiesel exhaustextractionimpingerparticulate matterreactive oxygen speciessamplingsoottoxicity

Substanzen

Particulate MatterVehicle EmissionsAir PollutantsReactive Oxygen SpeciesSuspensions

Autor:innen und Institutionen

  • Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden.
  • CBRN Defence and Security, Swedish Defence Research Agency, Umeå, Sweden.
  • Department of Applied Physics and Electronics, Thermochemical Energy Conversion Laboratory, Umeå University, Umeå, Sweden.

ORCID-Profile: Oskari J Uski

Förderung

  • Swedish Heart Lung Foundation
  • Västerbotten County Council Spearhead Research Grant
  • Swedish Research Council for health working life and welfare (FORTE)
  • Hjärt-Lungfonden
  • Forskningsrådet om Hälsa, Arbetsliv och Välfärd

Zitieren

APA

Uski, O. J., Rankin, G. D., Wingfors, H., Magnusson, R., Boman, C., Muala, A., Blomberg, A., Bosson, J., & Sandström, T. (2024). In vitro toxicity evaluation in A549 cells of diesel particulate matter from two different particle sampling systems and several resuspension media. Journal of Applied Toxicology. https://doi.org/10.1002/jat.4616

Vancouver

Uski OJ, Rankin GD, Wingfors H, Magnusson R, Boman C, Muala A, et al. In vitro toxicity evaluation in A549 cells of diesel particulate matter from two different particle sampling systems and several resuspension media. Journal of Applied Toxicology. 2024. doi:10.1002/jat.4616

BibTeX
@article{Uski2024,
  author = {Uski, Oskari J and Rankin, Gregory D and Wingfors, Håkan and Magnusson, Roger and Boman, Christoffer and Muala, Ala and Blomberg, Anders and Bosson, Jenny and Sandström, Thomas},
  title = {In vitro toxicity evaluation in A549 cells of diesel particulate matter from two different particle sampling systems and several resuspension media},
  journal = {Journal of Applied Toxicology},
  year = {2024},
  doi = {10.1002/jat.4616}
}
Kostenlos starten →