A biomechanical study of tendon adhesion reduction using a biodegradable barrier in a rabbit model
Journal of Applied Biomaterials · 1990
DOI: 10.1002/jab.770010104 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Biomaterials, 1990. Verfasst von R J Meislin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Hospital for Joint Diseases Orthopaedic Institute, New York, NY 10003. Hauptthemen laut MEDLINE: Bandages, Cellulose, Oxidized. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
Adhesion formation associated with tendon surgery is a widespread problem in which a healing tendon becomes adherent via scar tissue to surrounding structures such as bone, muscle, skin, tendon sheath, or other tendons. A model is described in which adhesions were generated reproducibly between the plantaris and Achilles tendons of the rabbit using a partial tenotomy, a Bunnel suture, and immobilization. Using this model, the effect of an absorbable barrier, INTERCEED (TC7), INTERCEED (TC7) Absorbable Adhesion Barrier is a trademark of Johnson & Johnson Patient Care Inc. on adhesion formation was investigated. This material, which is a fabric comprised of oxidized regenerated cellulose, was found to diminish significantly the extent and severity of intertendinous adhesions, assessed both mechanically and histologically. No evidence of a foreign body reaction was observed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Bioengineering, Hospital for Joint Diseases Orthopaedic Institute, New York, NY 10003.
Zitieren
APA
Meislin, R. J., Wiseman, D. M., Alexander, H., Cunningham, T., Linsky, C., Carlstedt, C., Pitman, M., & Casar, R. (1990). A biomechanical study of tendon adhesion reduction using a biodegradable barrier in a rabbit model. Journal of Applied Biomaterials. https://doi.org/10.1002/jab.770010104
Vancouver
Meislin RJ, Wiseman DM, Alexander H, Cunningham T, Linsky C, Carlstedt C, et al. A biomechanical study of tendon adhesion reduction using a biodegradable barrier in a rabbit model. Journal of Applied Biomaterials. 1990. doi:10.1002/jab.770010104
BibTeX
@article{Meislin1990,
author = {Meislin, R J and Wiseman, D M and Alexander, H and Cunningham, T and Linsky, C and Carlstedt, C and Pitman, M and Casar, R},
title = {A biomechanical study of tendon adhesion reduction using a biodegradable barrier in a rabbit model},
journal = {Journal of Applied Biomaterials},
year = {1990},
doi = {10.1002/jab.770010104}
}
EUVIMED