Background
Virtual reality (VR) is becoming increasingly popular in radiology, with a variety of diagnostic applications being tested. However, VR is yet to be tested in the context of MRI studies. This study evaluated the agreement between a VR headset and a standard radiology workstation in grading meniscus lesions on knee MRI.
Methods
Fifty‐two knee MRIs were reviewed by a consultant musculoskeletal radiologist and a radiology resident. Each interpreted the examinations on a diagnostic screen and then re‐evaluated them using a VR headset. Meniscus lesions were graded using Lotysch's five‐segment classification. Agreement was assessed using Cohen's kappa and descriptive statistics, with significance at p < 0.05.
Results
Cohen's kappa was not always calculable due to asymmetry in data. The consultant showed moderate‐to‐near‐perfect agreement between VR and standard screens, 76% for the medial and 87% for the lateral meniscus. The resident showed moderate to minor agreement, 64% for the medial and 70% for the lateral meniscus. Agreement for nonpathological segments was high: 94% (consultant) and 76% (resident). Agreement dropped for pathological segments, particularly type 2b superior lesions (29% consultant and 0% resident).
Conclusions
VR headsets demonstrate strong comparability for excluding meniscal lesions and moderate accuracy in grading pathology, although agreement for pathological segments was limited. Although not a replacement for diagnostic screens, they may be useful in select cases. As technology advances, VR could support remote interpretation and supplement traditional radiology workflows.
Zitieren
APA
Saliba, T., & Pather, S. (2026). Comparing Virtual Reality Headsets With Standard Diagnostic Workstations for MRI Grading of Knee Meniscus Lesions: A Pilot Study. iRADIOLOGY, 4(5), 412-423. https://doi.org/10.1002/ird3.70099
Vancouver
Saliba T, Pather S. Comparing Virtual Reality Headsets With Standard Diagnostic Workstations for MRI Grading of Knee Meniscus Lesions: A Pilot Study. iRADIOLOGY. 2026;4(5):412-423. doi:10.1002/ird3.70099
BibTeX
@article{Saliba2026,
author = {Saliba, Thomas and Pather, Sanjiva},
title = {Comparing Virtual Reality Headsets With Standard Diagnostic Workstations for MRI Grading of Knee Meniscus Lesions: A Pilot Study},
journal = {iRADIOLOGY},
year = {2026},
volume = {4},
number = {5},
pages = {412--423},
doi = {10.1002/ird3.70099}
}
EUVIMED