EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Can molecular oscillation technology be used as an alternative to acid injection to prevent the clogging of emitters in drip irrigation systems?

Servet Tekin, Attila Yazar

Irrigation and Drainage · 2025-04 · 74 (2) · 586-599

DOI: 10.1002/ird.3046 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Irrigation and Drainage, online erschienen am 18.10.2024. Verfasst von Servet Tekin und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, molecular oscillation technology (Merus ring), developed to prevent calcification, biofilm formation and corrosion in piping in industrial water treatment systems, was compared as an alternative to acid injection to prevent the clogging of emitters by chemicals, and fresh and saline water were compared on the basis of system performance parameters (coefficient of variation, distribution uniformity, Christiansen uniformity, emission uniformity) and economic aspects. The results revealed that both acid injection and the Merus ring in saline and fresh water resulted in significantly higher average emitter flow rates than the control treatment. Both the Merus ring and the acid injection achieved higher performance parameters with fresh water than with saline water. Acid injection was found to be more effective in preventing clogging of the emitters than the Merus ring when saline water was used. Compared with fresh water, saline water increases emitter clogging. The economic analysis revealed that the Merus ring was more economical ($204.3 ha −1 ) than acid injection with both fresh water ($318.2 ha −1 ) and saline water ($578.6 ha −1 ). Therefore, the Merus ring could be a reliable and environmentally friendly alternative to acid injection to prevent the clogging of emitters in drip systems when saline water is used.

Zitieren

APA

Tekin, S., & Yazar, A. (2025). Can molecular oscillation technology be used as an alternative to acid injection to prevent the clogging of emitters in drip irrigation systems?. Irrigation and Drainage, 74(2), 586-599. https://doi.org/10.1002/ird.3046

Vancouver

Tekin S, Yazar A. Can molecular oscillation technology be used as an alternative to acid injection to prevent the clogging of emitters in drip irrigation systems?. Irrigation and Drainage. 2025;74(2):586-599. doi:10.1002/ird.3046

BibTeX
@article{Tekin2025,
  author = {Tekin, Servet and Yazar, Attila},
  title = {Can molecular oscillation technology be used as an alternative to acid injection to prevent the clogging of emitters in drip irrigation systems?},
  journal = {Irrigation and Drainage},
  year = {2025},
  volume = {74},
  number = {2},
  pages = {586--599},
  doi = {10.1002/ird.3046}
}
Kostenlos starten →