EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flexible electromyography sensor with in situ gelation hydrogel for early diagnosis of lumbar spine diseases

Mingxuan Zhang, Mingming Hao, Guoqiang Ren, Yinchao Zhao, Chujie Lv, Yizhang Xia, Wei Wang, Wei Chen, Yi Chen, Lianhui Li, Qifeng Lu, Ting Zhang

InfoMat · 2025-12 · 7 (12)

DOI: 10.1002/inf2.70066 ↗

Kurz gefasst

Fachartikel in der Zeitschrift InfoMat, online erschienen am 17.09.2025. Verfasst von Mingxuan Zhang und 11 weiteren Autor:innen. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prolonged sitting is a major risk factor for lumbar spine disorders, significantly affecting both physical and mental health. However, conventional clinical diagnosis primarily relies on imaging evaluations conducted after symptom onset, often missing opportunities for early intervention and allowing for disease progression. To address this, this paper presents a diagnostic method based on electromyography (EMG) using an adaptive flexible electromyography sensor (FES). The FES consists of a thermo‐responsive in situ gelation hydrogel and flexible mesh electrode patch. The hydrogel undergoes a sol–gel transition at body temperature, enabling conformal skin contact and strong adhesion. As a result, the adhesion of the FES is 15 times stronger than that of conventional EMG electrodes. Consequently, the contact impedance is significantly reduced to 40 kΩ/cm 2 at 10 Hz, and a high signal‐to‐noise ratio of 23.28 dB is achieved, allowing for the effective monitoring of subtle electrophysiological signals during prolonged sitting. Overall, this research provides a foundation for the early‐stage diagnosis of lumbar disorders, facilitating the transition of lumbar disease management from reactive treatment to proactive prevention. image

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation

Zitieren

APA

Zhang, M., Hao, M., Ren, G., Zhao, Y., Lv, C., Xia, Y., Wang, W., Chen, W., Chen, Y., Li, L., Lu, Q., & Zhang, T. (2025). Flexible electromyography sensor with in situ gelation hydrogel for early diagnosis of lumbar spine diseases. InfoMat, 7(12). https://doi.org/10.1002/inf2.70066

Vancouver

Zhang M, Hao M, Ren G, Zhao Y, Lv C, Xia Y, et al. Flexible electromyography sensor with in situ gelation hydrogel for early diagnosis of lumbar spine diseases. InfoMat. 2025;7(12). doi:10.1002/inf2.70066

BibTeX
@article{Zhang2025,
  author = {Zhang, Mingxuan and Hao, Mingming and Ren, Guoqiang and Zhao, Yinchao and Lv, Chujie and Xia, Yizhang and Wang, Wei and Chen, Wei and Chen, Yi and Li, Lianhui and Lu, Qifeng and Zhang, Ting},
  title = {Flexible electromyography sensor with in situ gelation hydrogel for early diagnosis of lumbar spine diseases},
  journal = {InfoMat},
  year = {2025},
  volume = {7},
  number = {12},
  doi = {10.1002/inf2.70066}
}
Kostenlos starten →