High‐performance 110 kVp hard x‐ray detector based on all‐crystalline‐surface passivated perovskite single crystals
InfoMat · 2024-08 · 6 (8)
DOI: 10.1002/inf2.12560 ↗Kurz gefasst
Fachartikel in der Zeitschrift InfoMat, online erschienen am 18.06.2024. Verfasst von Juyoung Ko und 9 weiteren Autor:innen. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agency for Defense Development, Defense Acquisition Program Administration, Korea Institute of Energy Technology Evaluation and Planning.
Abstract (Originalsprache)
Halide perovskite single crystals (SCs) have attracted much attention for their application in high‐performance x‐ray detectors owing to their desirable properties, including low defect density, high mobility–lifetime product ( μτ ), and long carrier diffusion length. However, suppressing the inherent defects in perovskites and overcoming the ion migration primarily caused by these defects remains a challenge. This study proposes a facile process for dipping Cs 0.05 FA 0.9 MA 0.05 PbI 3 SCs synthesized by a solution‐based inverse temperature crystallization method into a 2‐phenylethylammonium iodide (PEAI) solution to reduce the number of defects, inhibit ion migration, and increase x‐ray sensitivity. Compared to conventional spin coating, this simple dipping process forms a two‐dimensional PEA 2 PbI 4 layer on all SC surfaces without further treatment, effectively passivating all surfaces of the inherently defective SCs and minimizing ion migration. As a result, the PEAI‐treated perovskite SC‐based x‐ray detector achieves a record x‐ray sensitivity of 1.3 × 10 5 μC Gy air −1 cm −2 with a bias voltage of 30 V at realistic clinical dose rates of 1–5 mGy s −1 (peak potential of 110 kVp), which is 6 times more sensitive than an untreated SC‐based detector and 3 orders of magnitude more sensitive than a commercial α‐Se‐based detector. Furthermore, the PEAI‐treated‐perovskite SC‐based x‐ray detector exhibits a low detection limit (73 nGy s −1 ), improved x‐ray response, and clear x‐ray images by a scanning method, highlighting the effectiveness of the PEAI dipping approach for fabricating next‐generation x‐ray detectors. image
Förderung
- Agency for Defense Development
- Defense Acquisition Program Administration
- Korea Institute of Energy Technology Evaluation and Planning
Zitieren
APA
Ko, J., Park, B., Byun, J., Pandey, S., Jo, A., Lee, J., Lee, W., Lee, J., Park, N., & Lee, M. (2024). High‐performance 110 kVp hard x‐ray detector based on all‐crystalline‐surface passivated perovskite single crystals. InfoMat, 6(8). https://doi.org/10.1002/inf2.12560
Vancouver
Ko J, Park B, Byun J, Pandey S, Jo A, Lee J, et al. High‐performance 110 kVp hard x‐ray detector based on all‐crystalline‐surface passivated perovskite single crystals. InfoMat. 2024;6(8). doi:10.1002/inf2.12560
BibTeX
@article{Ko2024,
author = {Ko, Juyoung and Park, Beomjun and Byun, Jangwon and Pandey, Sandeep and Jo, Ajin and Lee, Joo‐Hong and Lee, Wonho and Lee, Jin‐Wook and Park, Nam‐Gyu and Lee, Man‐Jong},
title = {High‐performance 110 kVp hard x‐ray detector based on all‐crystalline‐surface passivated perovskite single crystals},
journal = {InfoMat},
year = {2024},
volume = {6},
number = {8},
doi = {10.1002/inf2.12560}
}
EUVIMED