Feasibility and effectiveness of the novel HemoClear microfiltration cell‐salvage system in cesarean sections in South Africa

Nndwammbi C Ramatsea iD, Marnus Booyens iD, Joseph B Sempa iD, Angélique B van 't Wout iD, Edwin Turton iD, Arno P Nierich iD

International Journal of Gynecology & Obstetrics · 2026

DOI: 10.1002/ijgo.70313 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Gynecology & Obstetrics, 2026. Verfasst von Nndwammbi C Ramatsea und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, The University of the Free State, Bloemfontein, South Africa. Hauptthemen laut MEDLINE: Cesarean Section, Operative Blood Salvage, Blood Transfusion, Autologous. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Universiteit van die Vrystaat.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To test the feasibility and effectiveness of implementing the HemoClear microfiltration cell‐salvage system for cesarean sections in South Africa.

Methods

We conducted a prospective experimental single‐arm feasibility study collecting and processing blood from 20 adult women undergoing cesarean section in Pelonomi Tertiary Hospital, Bloemfontein. Samples obtained from the blood salvaged during the cesarean section before (baseline) and after (concentrate and filtrate) the cell‐salvage procedure were tested for cellular, protein, electrolyte, and metabolic parameters, as well as blood coagulation and bacterial or amniotic fluid contamination.

Results

Median erythrocyte recovery using the HemoClear device was 75.5% (interquartile range [IQR], 63.8%–94.3%). An average volume of 826 ± 146 mL was processed in 15.3 ± 6.3 min, resulting in 266 ± 116 mL of cell concentrate. The filtration procedure washed away >75% of the α‐fetoprotein content in the concentrate, resulting in a median recovery of 24.0% (IQR, 21.4%–35.9%). Bacterial contamination was mostly consistent between baseline and concentrate for each patient and resulted mainly from normal skin flora. In six patients, nonskin species were detected.

Conclusion

This study shows the HemoClear system's adaptability to resource‐constrained environments, which opens the door for broader adoption of its use in similar resource‐constrained settings. The HemoClear cell‐salvage device is safe and efficient for intraoperative use in obstetric hemorrhage cases and can play an essential role in patient blood management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cesarean SectionOperative Blood SalvageBlood Transfusion, AutologousHumansFemaleSouth AfricaAdultProspective StudiesFeasibility StudiesPregnancyFiltration

Stichwörter der Autor:innen

HemoClearcesarean sectionhemorrhageintraoperative cell salvagelow‐middle–income countriestransfusion

Autor:innen und Institutionen

  • Department of Anaesthesiology, The University of the Free State, Bloemfontein, South Africa.
  • Department of Biostatistics, The University of the Free State, Bloemfontein, South Africa.
  • AlphaBiomics Limited, Newcastle upon Tyne, UK.
  • Van 't Wout Pharma Consulting, Amsterdam, The Netherlands.
  • HemoClear BV, Zwolle, The Netherlands.

ORCID-Profile: Nndwammbi C Ramatsea, Marnus Booyens, Joseph B Sempa, Angélique B van 't Wout, Edwin Turton, Arno P Nierich

Förderung

  • Universiteit van die Vrystaat

Zitieren

APA

Ramatsea, N. C., Booyens, M., Sempa, J. B., van 't Wout, A. B., Turton, E., & Nierich, A. P. (2026). Feasibility and effectiveness of the novel HemoClear microfiltration cell‐salvage system in cesarean sections in South Africa. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.70313

Vancouver

Ramatsea NC, Booyens M, Sempa JB, van 't Wout AB, Turton E, Nierich AP. Feasibility and effectiveness of the novel HemoClear microfiltration cell‐salvage system in cesarean sections in South Africa. International Journal of Gynecology & Obstetrics. 2026. doi:10.1002/ijgo.70313

BibTeX
@article{Ramatsea2026,
  author = {Ramatsea, Nndwammbi C and Booyens, Marnus and Sempa, Joseph B and van 't Wout, Angélique B and Turton, Edwin and Nierich, Arno P},
  title = {Feasibility and effectiveness of the novel HemoClear microfiltration cell‐salvage system in cesarean sections in South Africa},
  journal = {International Journal of Gynecology & Obstetrics},
  year = {2026},
  doi = {10.1002/ijgo.70313}
}
Kostenlos starten →