Anticoagulant therapy in pregnant women with mechanical and bioprosthetic heart valves
International Journal of Gynecology & Obstetrics · 2025
DOI: 10.1002/ijgo.15935 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Gynecology & Obstetrics, 2025. Verfasst von Haroun A Rhemtula und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics, Faculty of Health Sciences, University of Witwatersrand Medical School, Johannesburg, South Africa. Hauptthemen laut MEDLINE: Anticoagulants, Heart Valve Prosthesis, Pregnancy Complications, Cardiovascular, Bioprosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Objective
The aim of the present study was to review maternal and fetal outcomes in pregnant women with prosthetic heart valves.
Methods
A retrospective record review of pregnant women with prosthetic heart valves on anticoagulation was performed at the Specialist Cardiac Antenatal Clinic, Johannesburg South Africa from 2015 to 2023.
Results
Fifty pregnancies with mechanical heart valves and three with tissue valves, on anticoagulation for comorbid atrial fibrillation were identified. The majority were of African ethnicity at a mean age of 33 ± 6 years. Anti‐Xa adjusted enoxaparin was commenced at 10.5 ± 5.6 weeks' gestation until delivery in 48 (90.6%) pregnancies and warfarin was continued in five (9.4%) pregnancies. The live birth rates on enoxaparin and warfarin were 56.3% (95% confidence interval [CI]: 42.3–69.3) and 20.0% (95% CI: 2.0–64.0), respectively. There were 12 (22.6%) miscarriages at a mean of 11.3 ± 3.7 weeks' gestation, four (7.5%) intrauterine fetal deaths on warfarin and two (3.8%) warfarin embryopathy/fetopathy. The rates of antepartum/secondary postpartum bleeding and primary postpartum bleeding were 29.4% (95% CI: 18.6–43.1) and 5.9% (95% CI: 1.4–16.9), respectively. Maternal complications included anemia ( n = 11, 20.8%), arrhythmia ( n = 2, 3.8%), heart failure ( n = 2, 3.8%) and paravalvular leak ( n = 2, 3.8%). There was one (1.9%) mitral valve thrombosis and one (1.9%) stuck valve in pregnancies who defaulted warfarin prior to pregnancy. There were no maternal deaths.
Conclusion
Multidisciplinary management of pregnant women with prosthetic heart valves with anti‐Xa adjusted low molecular weight heparin throughout pregnancy represents an effective anticoagulation option for low‐middle‐income countries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Obstetrics, Faculty of Health Sciences, University of Witwatersrand Medical School, Johannesburg, South Africa.
- Department of Molecular Medicine and Hematology, Faculty of Health Sciences, University of Witwatersrand Medical School, Johannesburg, South Africa.
ORCID-Profile: Elise Schapkaitz
Zitieren
APA
Rhemtula, H. A., Schapkaitz, E., Jacobson, B., & Chauke, L. (2025). Anticoagulant therapy in pregnant women with mechanical and bioprosthetic heart valves. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.15935
Vancouver
Rhemtula HA, Schapkaitz E, Jacobson B, Chauke L. Anticoagulant therapy in pregnant women with mechanical and bioprosthetic heart valves. International Journal of Gynecology & Obstetrics. 2025. doi:10.1002/ijgo.15935
BibTeX
@article{Rhemtula2025,
author = {Rhemtula, Haroun A and Schapkaitz, Elise and Jacobson, Barry and Chauke, Lawrence},
title = {Anticoagulant therapy in pregnant women with mechanical and bioprosthetic heart valves},
journal = {International Journal of Gynecology & Obstetrics},
year = {2025},
doi = {10.1002/ijgo.15935}
}