Development of a semi‐automated tool to measure fetal abdominal wall thickness during ultrasound at 20 weeks' gestation

Suresh Seshadri, Sindhu Pudhukudi, Jayanti Vajiravelu, Ponnusamy Saravanan, Jon Hyett, Uma Ram iD

International Journal of Gynecology & Obstetrics · 2024

DOI: 10.1002/ijgo.15524 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift International Journal of Gynecology & Obstetrics, 2024. Verfasst von Suresh Seshadri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Mediscan Systems, Chennai, India. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Nomograms, Abdominal Wall. Die Arbeit nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To develop a semi‐automated tool for measuring fetal abdominal wall thickness (AWT). To validate the software using images captured by other centers and create a nomogram for fetal AWT between 18 and 20 weeks.

Methods

A semiautomated tool that measured AWT was developed using images captured at the routine 20‐week morphology scan. The software was developed using digital images captured routinely during scans of low‐risk women. Inter‐ and intraobserver reliability was assessed between manual and semi‐automated measures. The tool was validated using images acquired from other centers. Linear regression and quadratic polynomials were used to create a nomogram for AWT.

Results

The semi‐automated tool was able to measure AWT in all images. Interoperator reliability was 0.90 and 0.97 ( P < 0.05) for manual and semi‐automated methods, respectively. Measurement agreement varied between three operators from moderate to excellent (0.77, 0.87, 0.92), with overall agreement being good (0.85). The tool could be successfully applied to 89% of images from other centers. A nomogram was generated for AWT measurements of fetuses at 18–20 weeks in normal, low risk mothers.

Conclusion

Semi‐automated measurement of AWT was feasible using images captured during the routine 20‐week scan. This approach had lower inter‐ and intraobserver variability compared to manual measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalNomogramsAbdominal WallHumansFemalePregnancyReproducibility of ResultsGestational AgeSoftwareObserver VariationPregnancy Trimester, SecondAdult

Stichwörter der Autor:innen

abdominal wall thicknessautomated measurementfetal adiposityfetal growthgestational diabetes

Autor:innen und Institutionen

  • Mediscan Systems, Chennai, India.
  • Aster Fetal Medicine, Aster Medcity, Cochin, India.
  • Populations, Evidence and Technologies, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, UK.
  • Department of Diabetes, Endocrinology and Metabolism, George Eliot Hospital, Nuneaton, UK.
  • Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia.
  • Seethapathy Clinic and Hospital, Chennai, India.

ORCID-Profile: Uma Ram

Zitieren

APA

Seshadri, S., Pudhukudi, S., Vajiravelu, J., Saravanan, P., Hyett, J., & Ram, U. (2024). Development of a semi‐automated tool to measure fetal abdominal wall thickness during ultrasound at 20 weeks' gestation. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.15524

Vancouver

Seshadri S, Pudhukudi S, Vajiravelu J, Saravanan P, Hyett J, Ram U. Development of a semi‐automated tool to measure fetal abdominal wall thickness during ultrasound at 20 weeks' gestation. International Journal of Gynecology & Obstetrics. 2024. doi:10.1002/ijgo.15524

BibTeX
@article{Seshadri2024,
  author = {Seshadri, Suresh and Pudhukudi, Sindhu and Vajiravelu, Jayanti and Saravanan, Ponnusamy and Hyett, Jon and Ram, Uma},
  title = {Development of a semi‐automated tool to measure fetal abdominal wall thickness during ultrasound at 20 weeks' gestation},
  journal = {International Journal of Gynecology & Obstetrics},
  year = {2024},
  doi = {10.1002/ijgo.15524}
}
Kostenlos starten →