Pelvic floor ultrasound evaluation in the diagnosis of exposure of synthetic implanted materials in the lower urinary tract

Matteo Frigerio, Marta Barba iD, Giuseppe Marino, Silvia Volonte, Alice Cola

International Journal of Gynecology & Obstetrics · 2023

DOI: 10.1002/ijgo.14933 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Gynecology & Obstetrics, 2023. Verfasst von Matteo Frigerio und 4 weiteren Autor:innen. Beteiligte Einrichtung: Monza-Ospedale San Gerardo, Monza, Italy. Hauptthemen laut MEDLINE: Urinary Incontinence, Stress, Suburethral Slings. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the diagnostic performance of pelvic floor ultrasound (PFUS) to recognize prosthetics exposure in the bladder and/or urethra in women with lower urinary tract symptoms (LUTS).

Methods

A cross‐sectional study evaluating patients with LUTS after mesh/sling surgery. PFUS was performed with both transvaginal (TVUS) and translabial (TLUS) approaches. A distance of 1 mm or less from the bladder and/or urethra was considered highly suspect for mesh exposure. After PFUS, patients underwent diagnostic urethrocystoscopy.

Results

A total of 100 consecutive women were analyzed. According to urethrocystoscopy, the rate of tape exposure in the lower urinary tract was 3%. PFUS showed 100% sensitivity and 98%–100% specificity in detecting lower urinary tract mesh exposure. The negative predictive value was 100% and the positive predictive value ranged from 33% to 50% for urethral and 100% for bladder exposure.

Conclusions

PFUS represents an effective and reliable non‐invasive screening test to exclude prosthetics exposure in the bladder and/or urethra in women with LUTS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary Incontinence, StressSuburethral SlingsHumansFemaleUrinary BladderPelvic FloorCross-Sectional Studies

Stichwörter der Autor:innen

cystoscopylower urinary tractmesh exposuremidurethral slingpelvic floor ultrasoundprosthetics material

Autor:innen und Institutionen

  • Monza-Ospedale San Gerardo, Monza, Italy.
  • University of Milano-Bicocca, Monza, Italy.

ORCID-Profile: Marta Barba

Zitieren

APA

Frigerio, M., Barba, M., Marino, G., Volonte, S., & Cola, A. (2023). Pelvic floor ultrasound evaluation in the diagnosis of exposure of synthetic implanted materials in the lower urinary tract. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.14933

Vancouver

Frigerio M, Barba M, Marino G, Volonte S, Cola A. Pelvic floor ultrasound evaluation in the diagnosis of exposure of synthetic implanted materials in the lower urinary tract. International Journal of Gynecology & Obstetrics. 2023. doi:10.1002/ijgo.14933

BibTeX
@article{Frigerio2023,
  author = {Frigerio, Matteo and Barba, Marta and Marino, Giuseppe and Volonte, Silvia and Cola, Alice},
  title = {Pelvic floor ultrasound evaluation in the diagnosis of exposure of synthetic implanted materials in the lower urinary tract},
  journal = {International Journal of Gynecology & Obstetrics},
  year = {2023},
  doi = {10.1002/ijgo.14933}
}